English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  The calibration of eROSITA on SRG

Dennerl, K., Andritschke, R., Braeuninger, H., Burkert, W., Burwitz, V., Emberger, V., et al. (2020). The calibration of eROSITA on SRG. In Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray. doi:10.1117/12.2562330.

Item is

Basic

show hide
Genre: Conference Paper

Files

show Files
hide Files
:
The calibration of eROSITA on SRG.pdf (Any fulltext), 12MB
 
File Permalink:
-
Name:
The calibration of eROSITA on SRG.pdf
Description:
-
OA-Status:
Visibility:
Private
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Dennerl, Konrad1, Author           
Andritschke, Robert1, Author           
Braeuninger, Heinrich1, Author           
Burkert, Wolfgang1, Author           
Burwitz, Vadim1, Author           
Emberger, Valentin1, Author           
Freyberg, Michael1, Author           
Friedrich, Peter1, Author           
Gaida, Roland1, Author           
Granato, Stefanie1, Author           
Hartner, Gisela1, Author           
Kienlin, Andreas von1, Author           
Meidinger, Norbert1, Author           
Menz, Benedikt1, Author           
Predehl, Peter1, Author           
Affiliations:
1High Energy Astrophysics, MPI for Extraterrestrial Physics, Max Planck Society, ou_159890              

Content

show
hide
Free keywords: -
 Abstract: The power of eROSITA (extended ROentgen Survey with an Imaging Telescope Array), the core instrument on the Russian–German Spectrum–Roentgen–Gamma (SRG) mission, is high sensitivity at high spectral, spatial, and temporal resolution over a large field of view. This is achieved by combining 7 coaligned X–ray telescope modules, each composed of 54 paraboloid / hyperboloid mirror shells in a Wolter–I geometry, to focus the X–rays through optical blocking filters onto PNCCDs with a total of 1 million pixels, providing a spectral resolution of 60 – 160 eV FWHM over an energy range 0.2 – 8 keV and a 1 degree field of view at a time resolution of 50 ms. In order to make full scientific use of the unique capabilities of eROSITA, all the individual components have to be calibrated. The initial ground calibration was done at the PANTER and PUMA facilities of MPE as well as at BESSY, and was supplemented by an in–orbit calibration. We report on the extensive and often challenging calibration activities performed on ground and in space.

Details

show
hide
Language(s): eng - English
 Dates: 2020-12-13
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1117/12.2562330
 Degree: -

Event

show
hide
Title: Conference on Space Telescopes and Instrumentation - Ultraviolet to Gamma Ray / SPIE Astronomical Telescopes + Instrumentation Conference
Place of Event: ELECTR NETWORK
Start-/End Date: 2020-12-14 - 2020-12-18

Legal Case

show

Project information

show

Source 1

show
hide
Title: Space Telescopes and Instrumentation 2020: Ultraviolet to Gamma Ray
Source Genre: Proceedings
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 11444 Sequence Number: 114444Q Start / End Page: - Identifier: -