Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  A streamlined workflow for automated cryo focused ion beam milling

Tacke, S., Erdmann, P., Wang, Z., Klumpe, S., Grange, M., Plitzko, J., et al. (2021). A streamlined workflow for automated cryo focused ion beam milling. Journal of Structural Biology, 213(3): 107743. doi:10.1016/j.jsb.2021.107743.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Tacke, Sebastian1, Autor
Erdmann, Philipp2, Autor           
Wang, Zhexin1, Autor
Klumpe, Sven2, Autor           
Grange, Michael1, Autor
Plitzko, Jürgen2, Autor           
Raunser, Stefan1, Autor
Affiliations:
1external, ou_persistent22              
2Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

Inhalt

einblenden:
ausblenden:
Schlagwörter: VITREOUS SECTIONS; CRYOELECTRON; TOMOGRAPHYBiochemistry & Molecular Biology; Biophysics; Cell Biology; Electron tomography; Focused ion beam; Cryo shield; Cryo shutter; Contamination; Automation;
 Zusammenfassung: Cryo-electron tomography (cryo-ET) is an emerging technique to study the cellular architecture and the structure of proteins at high resolution in situ. Most biological specimens are too thick to be directly investigated and are therefore thinned by milling with a focused ion beam under cryogenic conditions (cryo-FIB). This procedure is prone to contaminations, which makes it a tedious process, often leading to suboptimal results. Here, we present new hardware that overcomes the current limitations. We developed a new glove box and a high vacuum cryo transfer system and installed a stage heater, a cryo-shield and a cryo-shutter in the FIB milling microscope. This reduces the ice contamination during the transfer and milling process and simplifies the handling of the sample. In addition, we tested a new software application that automates the key milling steps. Together, these improvements allow for high-quality, high-throughput cryo-FIB milling. This paves the way for new types of experiments, which have been previously considered infeasible.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2021
 Publikationsstatus: Online veröffentlicht
 Seiten: 10
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: ISI: 000692079400005
DOI: 10.1016/j.jsb.2021.107743
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Journal of Structural Biology
  Kurztitel : J. Struct. Biol.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: San Diego, CA : Elsevier
Seiten: - Band / Heft: 213 (3) Artikelnummer: 107743 Start- / Endseite: - Identifikator: ISSN: 1047-8477
CoNE: https://pure.mpg.de/cone/journals/resource/954922650160