English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 angstrom

Turonova, B., Schur, F. K. M., Wan, W., & Briggs, J. A. G. (2017). Efficient 3D-CTF correction for cryo-electron tomography using NovaCTF improves subtomogram averaging resolution to 3.4 angstrom. Journal of Structural Biology, 199(3), 187-195. doi:10.1016/j.jsb.2017.07.007.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Turonova, B., Author
Schur, F. K. M., Author
Wan, W., Author
Briggs, John A. G.1, 2, Author           
Affiliations:
1European Molecular Biology Laboratory, External Organizations, ou_3346677              
2MRC Laboratory of Molecular Biology, External Organizations, Cambridge, GB, ou_3346673              

Content

show
hide
Free keywords: Cryo-electron microscopy Tomography Contrast transfer function Subtomogram averaging Defocus Reconstruction Weighted back projection particle electron cryomicroscopy ctf correction 3-dimensional structure in-situ defocus reconstruction microscopy projections micrographs Biochemistry & Molecular Biology Biophysics Cell Biology
 Abstract: Cryo-electron tomography (cryo-ET) allows cellular ultrastructures and macromolecular complexes to be imaged in three-dimensions in their native environments. Cryo-electron tomograms are reconstructed from projection images taken at defined tilt-angles. In order to recover high-resolution information from cryo-electron tomograms, it is necessary to measure and correct for the contrast transfer function (CTF) of the microscope. Most commonly, this is performed using protocols that approximate the sample as a two-dimensional (2D) plane. This approximation accounts for differences in defocus and therefore CTF across the tilted sample. It does not account for differences in defocus of objects at different heights within the sample; instead, a 3D approach is required. Currently available approaches for 3D-CTF correction are computationally expensive and have not been widely implemented. Here we simulate the benefits of 3D-CTF correction for high-resolution subtomogram averaging, and present a user-friendly, computationally-efficient 3D-CTF correction tool, NovaCTF, that is compatible with standard tomogram reconstruction workflows in IMOD. We validate the approach on synthetic data and test it using subtomogram averaging of real data. Consistent with our simulations, we find that 3D-CTF correction allows high-resolution structures to be obtained with much smaller subtomogram averaging datasets than are required using 2D-CTF. We also show that using equivalent dataset sizes, 3D-CTF correction can be used to obtain higher-resolution structures. We present a 3.4 angstrom resolution structure determined by subtomogram averaging.

Details

show
hide
Language(s): eng - English
 Dates: 2017
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: Other: WOS:000411921000003
DOI: 10.1016/j.jsb.2017.07.007
ISSN: 1047-8477
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Structural Biology
  Alternative Title : J. Struct. Biol.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 199 (3) Sequence Number: - Start / End Page: 187 - 195 Identifier: -