Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T

Brainovich, V., Sabatini, U., & Hagberg, G. (2009). Advantages of using multiple-echo image combination and asymmetric triangular phase masking in magnetic resonance venography at 3 T. Magnetic Resonance Imaging, 27(1), 23-37. doi:10.1016/j.mri.2008.05.006.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:

Urheber

einblenden:
ausblenden:
 Urheber:
Brainovich, V, Autor
Sabatini, U, Autor
Hagberg, GE1, Autor           
Affiliations:
1External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: The present work explores the possibility of localizing veins with magnetic resonance venography using susceptibility weighted imaging. It also seeks new approaches, directed by the spatial specificity of activated brain regions, that have sufficient precision for practical use in functional MRI studies. A 3D flow compensated multiple gradient echo sequence, featuring optimized T2* weighting within a reasonable time of acquisition (11 min) and a small voxel size (0.5×0.5×1 mm3), was used to acquire MR images at 3 T. Post-processing consisted of homodyne filtering, linear phase scaling and magnitude masking prior to minimum intensity projection (mIP). The multiple echo approach provided a satisfactory (48±7%) increase in signal-to-noise ratio with respect to conventional methods. Specific features of the blood oxygenation level-dependent phase effect were simulated and used for designing and exploring different phase masking methods in relation to vessel morphology and MRI voxel geometry. As with simulations, the best results were obtained with an asymmetric triangular phase masking, featuring an improved venographic contrast without any increase in the full-width at half-maximum. The multiple echo approach provided satisfactory vessel localization capacity by using asymmetric triangular phase masking and a 4-mm-thick mIP. The venographic contrast obtained enabled the detection of vessels with diameter down to approximately 500 μm, suggesting the applicability of the proposed method as an additional technique in fMRI studies.

Details

einblenden:
ausblenden:
Sprache(n):
 Datum: 2009-01
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1016/j.mri.2008.05.006
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance Imaging
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Elsevier
Seiten: - Band / Heft: 27 (1) Artikelnummer: - Start- / Endseite: 23 - 37 Identifikator: ISSN: 0730-725X
CoNE: https://pure.mpg.de/cone/journals/resource/954925533026