English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents

Bianciardi, M., Di Russo, F., Aprile, T., Maraviglia, B., & Hagberg, G. (2004). Combination of BOLD-fMRI and VEP recordings for spin-echo MRI detection of primary magnetic effects caused by neuronal currents. Magnetic Resonance Imaging, 22(10), 1429-1440. doi:10.1016/j.mri.2004.10.009.

Item is

Basic

show hide
Genre: Journal Article

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Bianciardi, M, Author
Di Russo, F, Author
Aprile, T, Author
Maraviglia, B, Author
Hagberg, GE1, Author              
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: In the present paper, for the first time, the feasibility to detect primary magnetic field changes caused by neuronal activity in vivo by spin-echo (SE) magnetic resonance imaging (MRI) is investigated. The detection of effects more directly linked to brain activity than secondary hemodynamic–metabolic changes would enable the study of brain function with improved specificity. However, the detection of neuronal currents by MRI is hampered by such accompanying hemodynamic changes. Therefore, SE image acquisition, rather than gradient-echo (GE) image acquisition, was preferred in the present work since the detection of primary neuronal and not blood oxygenation level-dependent (BOLD)-related effects may be facilitated by this approach. First of all, a precise spatiotemporal synchronization of image acquisition with the neuronal event had to be performed to avoid refocusing of the dephasing phenomenon during the course of the SE sequence. At this aim, we propose the combined use of visual evoked potential (VEP) recordings and BOLD-fMRI measurements prior to SE MRI scanning. Moreover, we exemplify by theory and experimentation how the control of artefactual signal changes due to BOLD and movement effects may be further improved by the experimental design. Finally, results from a pilot study using the proposed combination of VEP recordings and MRI techniques are reported, suggesting the feasibility of this method.

Details

show
hide
Language(s):
 Dates: 2004-12
 Publication Status: Published in print
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1016/j.mri.2004.10.009
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance Imaging
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Elsevier
Pages: - Volume / Issue: 22 (10) Sequence Number: - Start / End Page: 1429 - 1440 Identifier: ISSN: 0730-725X
CoNE: https://pure.mpg.de/cone/journals/resource/954925533026