English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments. Part I: Off-line studies with 219Rn and 221Fr

Goetz, S., Raeder, S., Block, M., Duellmann, C. E., Goetz, M., Jaeger, E., et al. (2021). Rapid extraction of short-lived isotopes from a buffer gas cell for use in gas-phase chemistry experiments. Part I: Off-line studies with 219Rn and 221Fr. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 995: 165090. doi:10.1016/j.nima.2021.165090.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Goetz, S.1, Author
Raeder, S.1, Author
Block, M.1, Author
Duellmann, Ch. E.1, Author
Goetz, M.1, Author
Jaeger, E.1, Author
Kaleja, O.2, Author           
Krier, J.1, Author
Lens, L.1, Author
Mistry, A. K.1, Author
Mokry, Ch.1, Author
Runke, J.1, Author
Thoerle-Pospiech, P.1, Author
Yakushev, A.1, Author
Affiliations:
1external, ou_persistent22              
2Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Content

show
hide
Free keywords: -
 MPINP: Speichertechnik - Abteilung Blaum
 Abstract: To study the chemical properties of the heaviest elements, a fast and
efficient stopping and extraction of the highly energetic residues from
heavy ion fusion reactions into the chemistry setup is essential.
Currently used techniques like Recoil Transfer Chambers (RTC) relying on
gas flow extraction provide high efficiencies for chemically
non-reactive volatile species, but operate at extraction times t(extr)
of about 0.5 s or more. Buffer Gas Cells (BGC) with electric and
Radio-Frequency (RF) fields offer much faster extraction times. Here, we
demonstrate the successful coupling of a BGC to a gas chromatography
setup as is used for studies of chemical properties of superheavy
elements. Using Ra-223 and Ac-225 recoil ion sources providing Rn-219
and Fr-221 ions for off-line tests, an extraction time t(extr) = 55(4)
ms and an extraction efficiency of 35(3)% were achieved for the
non-reactive Rn-219, while Fr-221 was retained. The results show a
BGC-based setup to be suitable for gas-phase experiments with
short-lived volatile transactinide elements like Cn and Fl with
half-lives substantially below 1 s.

Details

show
hide
Language(s):
 Dates: 2021-04-11
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier B.V.
Pages: - Volume / Issue: 995 Sequence Number: 165090 Start / End Page: - Identifier: ISSN: 0168-9002
CoNE: https://pure.mpg.de/cone/journals/resource/954925485716