  Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry

Manz, C., Götze, M., Frank, C., Zappe, A., & Pagel, K. (2022). Dextran as internal calibrant for N-glycan analysis by liquid chromatography coupled to ion mobility-mass spectrometry. Analytical and Bioanalytical Chemistry, 414(17), 5023-5031. doi:10.1007/s00216-022-04133-0.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
Manz2022_Article_DextranAsInternalCalibrantForN.pdf (Verlagsversion), 2MB
Name:
Manz2022_Article_DextranAsInternalCalibrantForN.pdf
Beschreibung:
-
OA-Status:
Hybrid
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2022
Copyright Info:
The Author(s)

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Manz, Christian1, 2, 3, Autor           
Götze, Michael1, 2, Autor
Frank, Clemens2, Autor
Zappe, Andreas1, 2, Autor
Pagel, Kevin1, 2, Autor           
Affiliations:
1Molecular Physics, Fritz Haber Institute, Max Planck Society, ou_634545              
2Department of Chemistry and Biochemistry, Freie Universität Berlin, Altensteinstr. 23A, 14195 Berlin, Germany, ou_persistent22              
3Analytical Chemistry, CMC, Silence Therapeutics GmbH, Robert-Rössle-Str. 10, 13125 Berlin, Germany, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: N-Glycan analysis; HILIC; Ion mobility spectrometry; Calibration; Glucose units; Collision cross sections
 Zusammenfassung: LC–MS is one of the most important tools for the comprehensive characterization of N-glycans. Despite many efforts to speed up glycan analysis via optimized sample preparation (e.g., faster enzyme digestion in combination with instant or rapid labeling dyes), a major bottleneck remains the rather long measurement times of HILIC chromatography. Further compli- cation arises from the necessity to concomitantly calibrate with an external standard to allow for accurate retention times and the conversion into more robust GU values. Here we demonstrate the use of an internal calibration strategy for HILIC chromatography to speed up glycan analysis. By reducing the number of utilized dextran oligosaccharides, the calibrant can be spiked directly into the sample such that external calibration runs are no longer required. The minimized dextran ladder shows accurate GU calibration with a minor deviation of well below 1% and can be applied without modifications in sample preparation or data processing. We further demonstrate the simultaneous use of the minimized dextran ladder as calibrant for the estimation of CCS values in traveling wave ion mobility spectrometry. In both cases, the minimized dextran ladder enables the measurement of calibrant and sample in a single HPLC run without losing information or accuracy.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2022-03-072022-05-162022-05-262022-07
 Publikationsstatus: Erschienen
 Seiten: 9
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1007/s00216-022-04133-0
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Analytical and Bioanalytical Chemistry
  Kurztitel : Anal. Bioanal. Chem.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Heidelberg : Springer-Verlag
Seiten: 9 Band / Heft: 414 (17) Artikelnummer: - Start- / Endseite: 5023 - 5031 Identifikator: ISSN: 1618-2642
CoNE: https://pure.mpg.de/cone/journals/resource/111006469468428