Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  First clinical application of a novel T1 mapping of the whole brain

Müller, S. J., Khadhraoui, E., Voit, D., Riedel, C. H., Frahm, J., & Ernst, M. S. (2022). First clinical application of a novel T1 mapping of the whole brain. The Neuroradiology Journal, in press. doi:10.1177/19714009221084244.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
3386920.pdf (Preprint), 2MB
Name:
3386920.pdf
Beschreibung:
-
OA-Status:
Keine Angabe
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Müller, S. J., Autor
Khadhraoui, E., Autor
Voit, D.1, Autor
Riedel, C. H., Autor
Frahm, J.1, Autor           
Ernst, M. S., Autor
Affiliations:
1Research Group Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society, ou_3350294              

Inhalt

einblenden:
ausblenden:
Schlagwörter: T1 mapping, quantitative magnetic resonance imaging, T1 relaxation time
 Zusammenfassung: Background: The aim of this study was to evaluate the reproducibility and clinical value of the novel single-shot T1 mapping method for rapid and accurate multi-slice coverage of the whole brain, described by Wang et al. 2015.

Methods: At a field strength of 3 Tesla, T1 mappings of 139 patients (51 of them without pathologic findings) and two repeats of five volunteers were performed at 0.5 mm in-plane resolution. Mean T1 values were determined in 18 manually segmented regions-of-interest without pathologic findings. Reproducibility of the repeated scans was calculated using mean coefficient of variations. Pathologies were grouped and separately evaluated.

Results: The mean age of the cohort was 49 (range 1-95 years). T1 relaxation times for ordinary brain and pathologies were in accordance with the literature values. Intra- and inter-subject reproducibility was excellent, and mean coefficient of variations were 2.4% and 3.8%, respectively.

Discussion: The novel rapid T1 mapping method is a reliable magnetic resonance imaging technique for identifying and quantifying normal brain structures and may thus serve as a basis for assessing pathologies. The fast and parallel online calculation enables a comfortable use in everyday clinical practice. We see a possible clinical value in a large spectrum of diseases, which should be investigated in further studies.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2022-04-21
 Publikationsstatus: Online veröffentlicht
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1177/19714009221084244
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: The Neuroradiology Journal
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: -
Seiten: - Band / Heft: - Artikelnummer: in press Start- / Endseite: - Identifikator: -