日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children

Röwer, L. M., Radke, K. L., Hußmann, J., Malik, H., Uelwer, T., Voit, D., Frahm, J., Wittsack, H. J., Harmeling, S., Pillekamp, F., & Klee, D. (2022). Comparison of cardiac volumetry using real-time MRI during free-breathing with standard cine MRI during breath-hold in children. Pediatric Radiology. doi:0.1007/s00247-022-05327-5.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-000A-8EE9-0 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000A-8EEA-F
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
3386933.pdf (出版社版), 3MB
ファイルのパーマリンク:
https://hdl.handle.net/21.11116/0000-000A-8EEB-E
ファイル名:
3386933.pdf
説明:
-
OA-Status:
閲覧制限:
公開
MIMEタイプ / チェックサム:
application/pdf / [MD5]
技術的なメタデータ:
著作権日付:
-
著作権情報:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Röwer, L. M., 著者
Radke, K. L., 著者
Hußmann, J., 著者
Malik, H., 著者
Uelwer, T., 著者
Voit, D.1, 著者
Frahm, J.1, 著者           
Wittsack, H. J., 著者
Harmeling, S., 著者
Pillekamp, F., 著者
Klee, D., 著者
所属:
1Research Group Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society, ou_3350294              

内容説明

表示:
非表示:
キーワード: Computer-assisted · Children · Heart · Image processing · Magnetic resonance imaging · Respiration · Volumetry
 要旨: Background Cardiac real-time magnetic resonance imaging (RT-MRI) provides high-quality images even during free-
breathing. Difficulties in post-processing impede its use in clinical routine.
Objective To demonstrate the feasibility of quantitative analysis of cardiac free-breathing RT-MRI and to compare image
quality and volumetry during free-breathing RT-MRI in pediatric patients to standard breath-hold cine MRI.
Materials and methods Pediatric patients (n= 22) received cardiac RT-MRI volumetry during free breathing (1.5 T; short axis;
30 frames per s) in addition to standard breath-hold cine imaging in end-expiration. Real-time images were binned retrospec-
tively based on electrocardiography and respiratory bellows. Image quality and volumetry were compared using the European
Cardiovascular Magnetic Resonance registry score, structure visibility rating, linear regression and Bland–Altman analyses.
Results Additional time for binning of real-time images was 2 min. For both techniques, image quality was rated good to
excellent. RT-MRI was significantly more robust against artifacts (P< 0.01). Linear regression revealed good correlations for
the ventricular volumes. Bland–Altman plots showed a good limit of agreement (LoA) for end-diastolic volume (left ventricle
[LV]: LoA -0.1 ± 2.7 ml/m2, right ventricle [RV]: LoA -1.9 ± 3.4 ml/m2), end-systolic volume (LV: LoA 0.4 ± 1.9 ml/m2,
RV: LoA 0.6 ± 2.0 ml/m2), stroke volume (LV: LoA -0.5± 2.3 ml/m2, RV: LoA -2.6± 3.3 ml/m2) and ejection fraction (LV:
LoA -0.5 ± 1.6%, RV: LoA -2.1 ± 2.8%).
Conclusion Compared to standard cine MRI with breath hold, RT-MRI during free breathing with retrospective respiratory
binning offers good image quality, reduced image artifacts enabling fast quantitative evaluations of ventricular volumes in
clinical practice under physiological conditions.

資料詳細

表示:
非表示:
言語:
 日付: 2022-01-132021-12-212022-02-162022-03-30
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: 査読あり
 識別子(DOI, ISBNなど): DOI: 0.1007/s00247-022-05327-5
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Pediatric Radiology
  省略形 : Pediatr Radiol
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Berlin, New York : Springer
ページ: - 巻号: - 通巻号: - 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 0301-0449
CoNE: https://pure.mpg.de/cone/journals/resource/0301-0449