English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Routine Collection of High-Resolution cryo-EM Datasets Using 200 KV Transmission Electron Microscope

Koh, A., Khavnekar, S., Yang, W., Karia, D., Cats, D., van der Ploeg, R., et al. (2022). Routine Collection of High-Resolution cryo-EM Datasets Using 200 KV Transmission Electron Microscope. Journal of Visualized Experiments, (181): e63519. doi:10.3791/63519.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Koh, Adrian1, Author
Khavnekar, Sagar2, Author           
Yang, Wen1, Author
Karia, Dimple1, Author
Cats, Dennis1, Author
van der Ploeg, Rob1, Author
Grollios, Fanis1, Author
Raschdorf, Oliver1, Author
Kotecha, Abhay1, Author
Nemecek, Daniel1, Author
Affiliations:
1external, ou_persistent22              
2Baumeister, Wolfgang / Molecular Structural Biology, Max Planck Institute of Biochemistry, Max Planck Society, ou_1565142              

Content

show
hide
Free keywords: EWALD SPHERE; PROTEINScience & Technology - Other Topics;
 Abstract: Cryo-electron microscopy (cryo-EM) has been established as a routine method for protein structure determination during the past decade, taking an ever-increasing share of published structural data. Recent advances in TEM technology and automation have boosted both the speed of data collection and quality of acquired images while simultaneously decreasing the required level of expertise for obtaining cryo-EM maps at sub-3 angstrom resolutions. While most of such high-resolution structures have been obtained using state-of-the-art 300 kV cryo-TEM systems, high-resolution structures can be also obtained with 200 kV cryo-TEM systems, especially when equipped with an energy filter. Additionally, automation of microscope alignments and data collection with real-time image quality assessment reduces system complexity and assures optimal microscope settings, resulting in increased yield of high-quality images and overall throughput of data collection. This protocol demonstrates the implementation of recent technological advances and automation features on a 200 kV cryo-transmission electron microscope and shows how to collect data for the reconstruction of 3D maps that are sufficient for de novo atomic model building. We focus on best practices, critical variables, and common issues that must be considered to enable the routine collection of such high-resolution cryo-EM datasets. Particularly the following essential topics are reviewed in detail: i) automation of microscope alignments, ii) selection of suitable areas for data acquisition, iii) optimal optical parameters for high-quality, high-throughput data collection, iv) energy filter tuning for zero-loss imaging, and v) data management and quality assessment. Application of the best practices and improvement of achievable resolution using an energy filter will be demonstrated on the example of apo-ferritin that was reconstructed to 1.6 angstrom, and Thermoplasma acidophilum 20S proteasome reconstructed to 2.1-angstrom resolution using a 200 kV TEM equipped with an energy filter and a direct electron detector.

Details

show
hide
Language(s): eng - English
 Dates: 2022-03-16
 Publication Status: Published online
 Pages: 25
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: ISI: 000830430700020
DOI: 10.3791/63519
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Visualized Experiments
  Other : Journal of Visualized Experiments: JoVE
  Abbreviation : J. Vis. Exp.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Rockville Pike, Bethesda MD : JoVE
Pages: - Volume / Issue: (181) Sequence Number: e63519 Start / End Page: - Identifier: ISSN: 1940-087X
CoNE: https://pure.mpg.de/cone/journals/resource/1940087X