English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Pulse Shape Discrimination for the CONUS Experiment in the sub-keV Regime

Stauber, J. (2022). Pulse Shape Discrimination for the CONUS Experiment in the sub-keV Regime. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Files

show Files
hide Files
:
Master_Thesis_Stauber.pdf (Any fulltext), 11MB
Name:
Master_Thesis_Stauber.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Stauber, Josef1, Author           
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Content

show
hide
Free keywords: -
 Abstract: The CONUS experiment operates four p-type High Purity Germanium (HPGe) detectors
with a total mass of 4 kg to measure Coherent Elastic neutrino Nucleus Scattering (CE_NS)
in the fully coherent regime. It is located in close vicinity (17 m) to the reactor core
of the nuclear power plant in Brokdorf, Germany. Next to a high neutrino flux and
a sub-keV detector energy threshold, a low background is crucial to measure CE_NS
with a high sensitivity. A new Data AcQuisition (DAQ) system for the ongoing RUN-5
allows the recording of the pulse shapes for the individual events. The Pulse Shape
Discrimination (PSD) method, optimized and further developed in this work, aims to
discriminate background events that originate from the outer, semi-active volume of the
HPGe diodes. It is based on a rise time ( ) study of each single event. Accounting for the
electronic response of the DAQ and preamplifier and by modeling the influence of the noise,
trustworthy physical pulses from a function generator are used to calibrate the PSD-cut in
the Region Of Interest (ROI) for CENS (sub-keV range). Based on a plausible definition
of figures of merit the signal efficiencies are optimized to achieve the best sensitivity for
CENS when applying the PSD-cut. With efficiencies between 94 and 97 %, an average
background reduction in all four detectors of about 15 % is achieved within the ROI.

Details

show
hide
Language(s):
 Dates: 2022
 Publication Status: Accepted / In Press
 Pages: VIII, 82 S.
 Publishing info: Heidelberg : Ruprecht-Karls-Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: Master

Event

show

Legal Case

show

Project information

show

Source

show