English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Optimized ultrahigh field parallel transmission workflow using rapid presaturated TurboFLASH transmit field mapping with a three-dimensional centric single-shot readout

Bosch, D., Bause, J., Geldschläger, O., & Scheffler, K. (2023). Optimized ultrahigh field parallel transmission workflow using rapid presaturated TurboFLASH transmit field mapping with a three-dimensional centric single-shot readout. Magnetic Resonance in Medicine, 89(1), 322-330. doi:10.1002/mrm.29459.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Bosch, D1, Author                 
Bause, J1, Author                 
Geldschläger, O2, Author                 
Scheffler, K1, Author                 
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              
2Research Group MR Spectroscopy and Ultra-High Field Methodology, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_2528692              

Content

show
hide
Free keywords: -
 Abstract: Purpose: To evaluate the usage of three-dimensional (3D) presaturated TurboFLASH (satTFL) for B+1 and B0 mapping on single channel and parallel transmission (pTx) systems.
Methods: B+1 maps recorded with 3D satTFL were compared to maps from three other 3D B+1 mapping sequences in an agar phantom. Furthermore, individual-channel B+1 maps of 18 human subjects were recorded with 3D satTFL using B+1
interferometry. A neural network was trained for masking of the maps.
Results: Out of the sequences compared satTFL was the only one with a mapping range exceeding well over 90°. In regions with lower flip angles there was high correspondence between satTFL and AFI. DREAM and double angle method also showed high qualitative similarity, however the magnitude differed from the other two measurements. The individual-channel B+1
maps were successfully used for pTx pulse calculation in a separate study.
Conclusion: 3D satTFL can record high-quality B+1 maps with a high dynamic range in a short time. Correspondence with AFI maps is high, while measurement duration is reduced drastically.

Details

show
hide
Language(s):
 Dates: 2022-092023-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.29459
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 89 (1) Sequence Number: - Start / End Page: 322 - 330 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149