  A multiple charging correction algorithm for broad supersaturation scanning cloud condensation nuclei (BS2-CCN) system

Kim, N., Su, H., Ma, N., Pöschl, U., & Cheng, Y. (2021). A multiple charging correction algorithm for broad supersaturation scanning cloud condensation nuclei (BS2-CCN) system. Atmospheric Measurement Techniques Discussions, 14. doi:https://amt.copernicus.org/preprints/amt-2022-188.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Gold

Creators

show
hide
 Creators:
Kim, Najin1, Author           
Su, Hang1, Author           
Ma, Nan1, Author           
Pöschl, Ulrich1, Author           
Cheng, Yafang1, Author           
Affiliations:
1Multiphase Chemistry, Max Planck Institute for Chemistry, Max Planck Society, ou_1826290              

Content

show
hide
Free keywords: -
 Abstract: High time resolution (~1 s) of aerosol hygroscopicity and CCN activity can be obtained with a Broad Supersaturation Scanning Cloud Condensation Nuclei (BS2-CCN) system. Based on a commercial DMT-CCNC, the newly designed diffusive inlet in the BS2-CCN realizes a broad supersaturation distribution in a chamber with a stable low sheath to aerosol flow ratio (SARs). In this way, a monotonic relation between activation fraction of aerosols (Fact) and critical activation supersaturation (Saerosol) can be obtained. The accuracy of the size-resolved aerosol hygroscopicity, κ, measured by the BS2-CCN system can be, however, hampered by multiply charged particles, i.e., resulting in the overestimation of κ values. As the BS2-CCN system uses multiple and continuous supersaturations in the chamber and the size-resolved Fact value is directly used to derive κ values, the multiple charging correction algorithm of the traditional CCNC where single supersaturation is applied does not work for the BS2-CCN observation. Here, we propose a new multiple charging correction algorithm to retrieve the true Fact value. Starting from the largest size bin, a new Fact value at a specific particle diameter (Dp) is updated from a measured activation spectra after removing both aerosol and CCN number concentration of multiply charged particles using a Kernel function with a given particle number size distribution. We compare the corrected activation spectra with laboratory aerosols for a calibration experiment and ambient aerosols during the 2021 Yellow-Sea Air Quality Studies (YES-AQ) campaign. The difference between corrected and measured κ values can be as large as 0.08 within the measured κ values between 0.11 and 0.37 among the selected samples, highlighting that multiple charge effect should be considered for the ambient aerosol measurement. Furthermore, we examine how particle number size distribution is linked to the deviation of activation spectra and κ values.

Details

show
hide
Language(s): eng - English
 Dates: 2021-07-20
 Publication Status: Published online
 Pages: 28
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Atmospheric Measurement Techniques Discussions
  Other : Atmos. Meas. Tech. Discuss.
  Abbreviation : AMTD
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 14 Sequence Number: - Start / End Page: - Identifier: ISSN: 1867-8610
CoNE: https://pure.mpg.de/cone/journals/resource/1867-8610