English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Polarization Independent Optical Coherence Tomography

Parmar, A., Sharma, G., & Singh, K. (2022). Polarization Independent Optical Coherence Tomography. IEEE Photonics Journal, 14(2). doi:10.1109/JPHOT.2022.3148721.

Item is

Files

show Files
hide Files
:
Polarization_Independent_Optical_Coherence_Tomography.pdf (Publisher version), 2MB
Name:
Polarization_Independent_Optical_Coherence_Tomography.pdf
Description:
-
OA-Status:
Not specified
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
This work is licensed under a Creative Commons Attribution 4.0 License. For more information, see https://creativecommons.org/licenses/by/4.0/

Locators

show

Creators

show
hide
 Creators:
Parmar, Asha1, 2, Author           
Sharma, Gargi1, Author           
Singh, Kanwarpal1, 2, 3, Author           
Affiliations:
1Singh Research Group, Research Groups, Max Planck Institute for the Science of Light, Max Planck Society, ou_3164411              
2Department of Physics, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany, ou_persistent22              
3Max-Planck-Zentrum für Physik und Medizin, Max Planck Institute for the Science of Light, Max Planck Society, ou_3164414              

Content

show
hide
Free keywords: optical coherence tomography, biomedical optical imaging, polarization artifacts, birefringence.
 Abstract: Optical coherence tomography (OCT) is a well established imaging modality for high-resolution three-dimensional imaging in clinical settings. While imaging, care must be taken to minimize the imaging artifacts related to the polarization differences between the sample and the reference signals. Current OCT systems adopt complicated mechanisms, such as the use of multiple detectors, polarization-maintaining fibers, polarization controllers to achieve polarization artifacts free sample images.
Often the polarization controllers need readjustment which is not suitable for clinical settings. In this work, we demonstrate a simple approach that can minimize the polarization-related artifacts in the OCT systems. Polarization artifact-free images are acquired using two orthogonally polarized reference signals where the orthogonal polarization is achieved using a Faraday mirror. In the current approach, only a single detector is required which makes the current approach compatiblewith swept-source or camera-basedOCT systems. Furthermore, no polarization controllers are used in the system which increases the system stability while minimizing the artifacts related to the sample birefringence, polarization change due to the sample scattering, and polarization change due to the optical fiber movements present in the system.

Details

show
hide
Language(s): eng - English
 Dates: 2022-03-04
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1109/JPHOT.2022.3148721
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: IEEE Photonics Journal
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York, NY : Institute of Electrical and Electronics Engineers
Pages: - Volume / Issue: 14 (2) Sequence Number: - Start / End Page: - Identifier: ISSN: 1943-0655
CoNE: https://pure.mpg.de/cone/journals/resource/1943-0655