日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  A testbed for performance studies of gas-liquid thermoelectric generators for waste heat harvesting

Wojciechowski, K. T., Borcuch, M., Musial, M., & Wyzga, P. (2022). A testbed for performance studies of gas-liquid thermoelectric generators for waste heat harvesting. Measurement, 203:, pp. 1-10. doi:10.1016/j.measurement.2022.111933.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-000B-44F3-6 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000B-44F5-4
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Wojciechowski, Krzysztof T.1, 著者
Borcuch, Marcin1, 著者
Musial, Michal1, 著者
Wyzga, Pawel2, 著者           
所属:
1External Organizations, ou_persistent22              
2Chemical Metal Science, Max Planck Institute for Chemical Physics of Solids, Max Planck Society, ou_1863405              

内容説明

表示:
非表示:
キーワード: -
 要旨: We describe a unique test platform for performance studies of thermoelectric generators (TEGs) with gas/liquid heat exchangers. The designed stand allows to simulate the real working conditions of TEG prototypes. It provides accurate measurements of key operational parameters of these devices in high precision laboratory regime. The testbed consists of a hot-gas control unit (HGCU) for examination of the heat exchanger (HHX) of the TEG, a cooling liquid control unit (CLCU), an automated control system (ACS) that allows to precisely set the requested experimental conditions, and a data acquisition system (DAS) that gathers data on temperature, fluids flow, pressure drops and electrical parameters of the TEG. The HGCU unit is a source of hot air, with mass flows in the range of 0-550 m(3)/h, maximum heat power P-H of 15 kW, and temperature range between 15 ? and 800 ?. The CLCU unit controls the flow and temperature of the liquid medium in the range from 10 ? to 110 ? and the mass flow of water m?(water) in the range of 0.006 - 1.2 m(3)/h. The designed testbed allows to evaluate the most important TEG performance parameters, such as: efficiencies of its TE converters, the effectiveness of heat exchangers, power losses due to pressure drops, and net power P-net generated, as well as the statistical uncertainties of the determination of these parameters. The testbed has been used for tests of various TEG prototypes. As an application example, we show results for a prototypical TEG with nominal power of 168 W designed for heat recovery from an automobile exhaust system. The device is based on a hexagonal, internally finned HHX, 24 TEM converters and 24 water-cooled cold heat exchangers (CHXs). The constructed testbed allows for a direct determination of all the factors which may influence the conversion efficiency of the TEG, as well as its net and gross electrical power output under varying heat source and heat sink parameters. The device allows to estimate the performance of the entire thermoelectric generation system as a whole and to identify individual components within the TEG which potentially need to be improved. Such a holistic approach to TEG parameter characterization was not presented or discussed in the literature so far.

資料詳細

表示:
非表示:
言語:
 日付: 2022
 出版の状態: オンラインで出版済み
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): ISI: 000861814100002
DOI: 10.1016/j.measurement.2022.111933
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Measurement
  その他 : Measurement
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: London : Elsevier
ページ: - 巻号: 203 通巻号: 111933 開始・終了ページ: 1 - 10 識別子(ISBN, ISSN, DOIなど): ISSN: 0263-2241
CoNE: https://pure.mpg.de/cone/journals/resource/958480272997