English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Investigation of a Charge Insensitive Volume in XENONnT, Analysis of Goodness-of-Fit Techniques, and Feasibility Studies for an Automated Krypton Assay System

Hammann, R. (2022). Investigation of a Charge Insensitive Volume in XENONnT, Analysis of Goodness-of-Fit Techniques, and Feasibility Studies for an Automated Krypton Assay System. Master Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Files

show Files
hide Files
:
hammann_robert_master_2022.pdf (Table of contents), 31MB
 
File Permalink:
-
Name:
hammann_robert_master_2022.pdf
Description:
-
OA-Status:
Visibility:
Private
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Hammann, Robert1, Author           
Affiliations:
1Division Prof. Dr. Manfred Lindner, MPI for Nuclear Physics, Max Planck Society, ou_904549              

Content

show
hide
Free keywords: -
 Abstract: The XENONnT experiment aims to directly detect dark matter (DM) particles using a dual-phase xenon time projection chamber (TPC). A particle interaction is detected via a prompt light signal and a delayed charge signal. In this work, three aspects essential for the direct search for DM are explored. To contribute to the general characterization of the XENONnT detector, the existence of a volume in the TPC is verified that exhibits a partial or complete loss of the charge signal. This region accounts for about 3 % of the active volume and is largest in the lower outer part of the TPC. The second part of this work focuses on a systematic study to find suitable goodnessof-fit (GOF) tests for the analysis of typical recoil bands of XENONnT. A strong dependence of the GOF test result on the binning is investigated and a solution using an irregular binning scheme is presented. Compared to several other GOF tests, the tests using this binning are best suited for identifying fits with incomplete models. In the third part, a contribution is made to the development of a system for the fully automated krypton assay of future DM detectors by providing a proof of concept for an automated gas chromatography system. The system parameter stability of the prototype is demonstrated under realistic conditions with relative errors below 0.15 %.

Details

show
hide
Language(s):
 Dates: 2022
 Publication Status: Accepted / In Press
 Pages: 125 S.
 Publishing info: Heidelberg : Ruprecht-Karls-Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: -
 Degree: Master

Event

show

Legal Case

show

Project information

show

Source

show