  Sensitivity and specificity of scanning laser polarimetry using the GDx

Munkwitz, S., Funk, J., Loeffler, K., Harbarth, U., & Kremmer, S. (2004). Sensitivity and specificity of scanning laser polarimetry using the GDx. British Journal of Ophthalmology, 88(9), 1142-1145. doi:10.1136/bjo.2003.036756.

Item is

Files

show Files

Locators

show
hide
Locator:
https://bjo.bmj.com/content/88/9/1142 (Publisher version)
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Munkwitz, S1, Author                 
Funk, J, Author
Loeffler, KU, Author
Harbarth, U, Author
Kremmer, S, Author
Affiliations:
1External Organizations, ou_persistent22              

Content

show
hide
Free keywords: -
 Abstract: Background/aims: To determine the sensitivity and the specificity of the GDx in the detection of (1) advanced glaucoma, (2) early glaucoma, and (3) nerve fibre bundle defects (NFBD).
Methods: Group A comprised 20 eyes with reproducible glaucomatous visual field defects confirmed by octopus perimetry, group B consisted of 10 eyes with normal visual fields but either glaucomatous NFBD or deterioration of the disc over time clearly visible upon flicker comparison, and group C included 16 eyes with glaucomatous or non-glaucomatous NFBD clearly visible on red free photographs. Forty four eyes of 22 healthy volunteers served as controls. The GDx printouts of all subjects were evaluated by three independent observers in a masked fashion and without the clinical picture of the optic disc. Two of the three observers (SK, UH) were GDx experts, one (KUL) was an untrained GDx user.
Results: Among the GDx experts, sensitivity/specificity was 100%/100% (SK) and 90%/100% (UH) in detecting advanced glaucoma, and 100%/100% (SK) and 90%/100% (UH) in detecting early glaucoma. The sensitivity in detecting NFBD was only 37.5% (SK and UH). For the untrained GDx user the corresponding values were 50%/100% (group A), 20%/100% (group B), and 12.5%/91% (group C).
Conclusion: Detection of (early) glaucoma damage by the GDx, evaluated by trained experts, can be extremely high. To optimise its benefit in clinical routine training in interpreting GDx printouts is highly recommended. Detection of localised NFBD is crucial, even for experts.

Details

show
hide
Language(s):
 Dates: 2004-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1136/bjo.2003.036756
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: British Journal of Ophthalmology
  Other : British Journal of Ophthalmology: BJO
  Abbreviation : Br J Ophthalmol
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London, UK : BMJ Publishing Group
Pages: - Volume / Issue: 88 (9) Sequence Number: - Start / End Page: 1142 - 1145 Identifier: ISSN: 0007-1161
CoNE: https://pure.mpg.de/cone/journals/resource/0007-1161