English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Photodetachment studies of negative ions at the Cryogenic Storage Ring

Müll, D. (2023). Photodetachment studies of negative ions at the Cryogenic Storage Ring. PhD Thesis, Ruprecht-Karls-Universität, Heidelberg.

Item is

Files

hide Files
:
dissertationdamianmüll.pdf (Publisher version), 28MB
Name:
dissertationdamianmüll.pdf
Description:
-
OA-Status:
Gold
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

hide
 Creators:
Müll, Damian1, Author           
Kreckel, Holger, Referee
Jochim, Selim, Referee
Affiliations:
1Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Content

hide
Free keywords: -
 MPINP: Quantendynamik - Abteilung Blaum
 Abstract: In the present work, experimental studies of the photodetachment process of the Si and Al4 systems are presented. The measurements were carried out at the Cryogenic
Storage Ring (CSR) facility located at the Max Planck Institute for Nuclear Physics
in Heidelberg. By storing Si for up to 2000 s in the T < 10K CSR environment, making use of the reduced blackbody radiation field inside the CSR, we were able
to monitor the decay of long-lived 2D states as well as the weakly bound 2P states. Employing a set of continuous wave and pulsed lasers, the lifetime for the 2P states
were found to be τ = (22.5 +/- 2.5)s. For the 2D states, a lower limit of τr > 5.7 h (within a confidence level of 90%) was measured. Furthermore, Multi-Configuration Dirac-Hartree-Fock (MCDHF) calculations were performed on the radiatiave lifetimes
of the respective states, which show very good agreement with the present measurement.
The second part of the studies focuses on the study of spontaneous cooling of stored Al4 ions at very long time scales. Here, we present measurements that allow us to monitor the cluster cooling rates for up to 30 min and we compare those results to previous measurements at a room temperature device. We find that the cooling time scale is limited by the redistribution of vibrational energy inside the molecule, which we call slow exchange model, and in combination with recurrent fluorescence for energies above the first electronic excited state, they match the observed cooling rates.

Details

hide
Language(s):
 Dates: 2023-01-10
 Publication Status: Accepted / In Press
 Pages: XIII, 113 S.
 Publishing info: Heidelberg : Ruprecht-Karls-Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.11588/heidok.00032839
 Degree: PhD

Event

show

Legal Case

show

Project information

show

Source

show