Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  An optofluidic antenna for enhancing the sensitivity of single-emitter measurements

Morales-Inostroza, L., Folz, J., Kühnemuth, R., Felekyan, S., Wieser, F., Seidel, C. A., et al. (2024). An optofluidic antenna for enhancing the sensitivity of single-emitter measurements. Nature Communications, 15: 2545. doi:10.1038/s41467-024-46730-w.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
s41467-024-46730-w.pdf (Verlagsversion), 2MB
Name:
s41467-024-46730-w.pdf
Beschreibung:
-
OA-Status:
Keine Angabe
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
-
Copyright Info:
-

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Morales-Inostroza, Luis1, 2, 3, Autor           
Folz, Julian4, Autor
Kühnemuth, Ralf4, Autor
Felekyan, Suren4, Autor
Wieser, Franz1, 2, 3, Autor           
Seidel, Claus A.M.4, Autor
Götzinger, Stephan1, 2, 3, Autor           
Sandoghdar, Vahid1, 2, 3, Autor           
Affiliations:
1Sandoghdar Division, Max Planck Institute for the Science of Light, Max Planck Society, ou_2364722              
2Sandoghdar Division, Max-Planck-Zentrum für Physik und Medizin, Max Planck Institute for the Science of Light, Max Planck Society, ou_3596674              
3Friedrich-Alexander-Universität Erlangen-Nürnberg, External Organizations, DE, ou_3487833              
4External Organizations, ou_persistent22              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Many single-molecule investigations are performed in fluidic environments, e.g., to avoid unwanted consequences of contact with surfaces. Diffusion of molecules in this arrangement limits the observation time and the number of collected photons, thus, compromising studies of processes with fast or slow dynamics. Here, we introduce a planar optofluidic antenna (OFA), which enhances the fluorescence signal from molecules by about 5 times per passage, leads to about 7-fold more frequent returns to the observation volume, and significantly lengthens the diffusion time within one passage. We use single-molecule multi-parameter fluorescence detection (sm-MFD), fluorescence correlation spectroscopy (FCS) and Förster resonance energy transfer (FRET) measurements to characterize our OFAs. The antenna advantages are showcased by examining both the slow (ms) and fast (50μs) dynamics of DNA four-way (Holliday) junctions with real-time resolution. The FRET trajectories provide evidence for the absence of an intermediate conformational state and introduce an upper bound for its lifetime. The ease of implementation and compatibility with various microscopy modalities make OFAs broadly applicable to a diverse range of studies.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2024-03-21
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: DOI: 10.1038/s41467-024-46730-w
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Nature Communications
  Kurztitel : Nat. Commun.
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: London : Nature Publishing Group
Seiten: - Band / Heft: 15 Artikelnummer: 2545 Start- / Endseite: - Identifikator: ISSN: 2041-1723
CoNE: https://pure.mpg.de/cone/journals/resource/2041-1723