  Turbulence in surgical suction heads as detected by MRI

Hanekop, G., Kollmeier, J. M., Frahm, J., Iwanowski, I., Khabbazzadeh, S., Kutschka, I., et al. (2023). Turbulence in surgical suction heads as detected by MRI. The Journal of Extra-Corporeal Technology, 55(2), 70-81. doi:10.1051/ject/2023015.

Item is

Files

show Files
hide Files
:
ject220039.pdf (Publisher version), 3MB
Name:
ject220039.pdf
Description:
-
OA-Status:
Hybrid
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Hanekop, G., Author
Kollmeier, Jost Michael1, Author           
Frahm, Jens1, Author           
Iwanowski, I., Author
Khabbazzadeh, S., Author
Kutschka, I., Author
Tirilomis, T., Author
Ulrich, C., Author
Friedrich, M.G., Author
Affiliations:
1Research Group Biomedical NMR, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society, ou_3350294              

Content

show
hide
Free keywords: Suction / Blood damage / Hemolysis / Turbulence / Magnetic Resonance Imaging
 Abstract: Background: Blood loss is common during surgical procedures, especially in open cardiac surgery. Allogenic blood transfusion is associated with increased morbidity and mortality. Blood conservation programs in cardiac surgery recommend re-transfusion of shed blood directly or after processing, as this decreases transfusion rates of allogenic blood. But aspiration of blood from the wound area is often associated with increased hemolysis, due to flow induced forces, mainly through development of turbulence. Methods: We evaluated magnetic resonance imaging (MRI) as a qualitative tool for detection of turbulence. MRI is sensitive to flow; this study uses velocity-compensated T1-weighted 3D MRI for turbulence detection in four geometrically different cardiotomy suction heads under comparable flow conditions (0–1250 mL/min). Results: Our standard control suction head Model A showed pronounced signs of turbulence at all flow rates measured, while turbulence was only detectable in our modified Models 1–3 at higher flow rates (Models 1 and 3) or not at all (Model 2). Conclusions: The comparison of flow performance of surgical suction heads with different geometries via acceleration-sensitized 3D MRI revealed significant differences in turbulence development between our standard control Model A and the modified alternatives (Models 1–3). As flow conditions during measurement have been comparable, the specific geometry of the respective suction heads must have been the main factor responsible. The underlying mechanisms and causative factors can only be speculated about, but as other investigations have shown, hemolytic activity is positively associated with degree of turbulence. The turbulence data measured in this study correlate with data from other investigations about hemolysis induced by surgical suction heads. The experimental MRI technique used showed added value for further elucidating the underlying physical phenomena causing blood damage due to non-physiological flow.

Details

show
hide
Language(s): eng - English
 Dates: 2023-06-28
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1051/ject/2023015
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : ---
Grant ID : -
Funding program : -
Funding organization : -

Source 1

show
hide
Title: The Journal of Extra-Corporeal Technology
  Other : J Extra Corpor Technol
  Abbreviation : JECT
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: American Society of Extra-Corporeal Technology
Pages: - Volume / Issue: 55 (2) Sequence Number: - Start / End Page: 70 - 81 Identifier: Other: ISSN
CoNE: https://pure.mpg.de/cone/journals/resource/0022-1058