English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Polarimetric calibration of a spectropolarimeter instrument with high precision: Sunrise chromospheric infrared spectropolarimeter (SCIP) for the sunrise iii balloon telescope

Kawabata, Y., Katsukawa, Y., Kubo, M., Anan, T., Ichimoto, K., Shinoda, K., et al. (2022). Polarimetric calibration of a spectropolarimeter instrument with high precision: Sunrise chromospheric infrared spectropolarimeter (SCIP) for the sunrise iii balloon telescope. Applied Optics, 61, 9716. doi:10.1364/AO.472516.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Kawabata, Yusuke, Author
Katsukawa, Yukio, Author
Kubo, Masahito, Author
Anan, Tetsu, Author
Ichimoto, Kiyoshi, Author
Shinoda, Kazuya, Author
Tsuzuki, Toshihiro, Author
Uraguchi, Fumihiro, Author
Nagata, Shin'ichi, Author
Oba, Takayoshi, Author
Expósito, David Hernández, Author
Sánchez Gómez, Antonio, Author
Orozco Suárez, David, Author
Balaguer Jiménz, María, Author
Bailón Martínez, Eduardo, Author
Morales Fernández, José Miguel, Author
Moreno Mantas, Antonio, Author
del Toro Iniesta, Jose Carlos, Author
Gandorfer, Achim1, Author           
Feller, Alex1, Author           
Affiliations:
1Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society, ou_1832289              

Content

show
hide
Free keywords: -
 Abstract: The Sunrise chromospheric infrared spectropolarimeter (SCIP) installed in the international balloon experiment sunrise iii will perform spectropolarimetric observations in the near-infrared band to measure solar photospheric and chromospheric magnetic fields simultaneously. The main components of SCIP for polarization measurements are a rotating wave plate, polarization beam splitters, and CMOS imaging sensors. In each of the sensors, SCIP records the orthogonal linearly polarized components of light. The polarization is later demodulated on-board. Each sensor covers one of the two distinct wavelength regions centered at 770 and 850 nm. To retrieve the proper circular polarization, the new parameter R , defined as the 45° phase shifted component of Stokes V in the modulation curve, is introduced. SCIP is aimed at achieving high polarization precision ( 1 σ < 3 × 10 − 4 of continuum intensity) to capture weak polarization signals in the chromosphere. The objectives of the polarization calibration test presented in this paper are to determine a response matrix of SCIP and to measure its repeatability and temperature dependence to achieve the required polarization precision. Tolerances of the response matrix elements were set after considering typical photospheric and chromospheric polarization signal levels. We constructed a feed optical system such that a telecentric beam can enter SCIP with the same f -number as the light distribution instrument of the sunrise iii telescope. A wire-grid linear polarizer and achromatic wave plate were placed before SCIP to produce the known polarization. The obtained response matrix was close to the values expected from the design. The wavelength and spatial variations, repeatability, and temperature dependence of the response matrix were confirmed to be smaller than tolerances.

Details

show
hide
Language(s):
 Dates: 2022
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1364/AO.472516
ISSN: 0003-6935
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Applied Optics
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 61 Sequence Number: - Start / End Page: 9716 Identifier: -