English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Accelerated 2D Cartesian MRI with an 8-channel local B0 coil array combined with parallel imaging

Tian, R., Uecker, M., Davids, M., Thielscher, A., Buckenmaier, K., Holder, O., et al. (2024). Accelerated 2D Cartesian MRI with an 8-channel local B0 coil array combined with parallel imaging. Magnetic Resonance in Medicine, 91(2), 443-465. doi:10.1002/mrm.29799.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Tian, R1, Author                 
Uecker, M, Author
Davids, M, Author
Thielscher, A, Author                 
Buckenmaier, K1, Author                 
Holder, O1, Author           
Steffen, T1, Author           
Scheffler, K1, Author                 
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Purpose: In MRI, the magnetization of nuclear spins is spatially encoded with linear gradients and radiofrequency receivers sensitivity profiles to produce images, which inherently leads to a long scan time. Cartesian MRI, as widely adopted for clinical scans, can be accelerated with parallel imaging and rapid magnetic field modulation during signal readout. Here, by using an 8-channel local B0 coil array, the modulation scheme optimized for sampling efficiency is investigated to speed up 2D Cartesian scans. Theory and methods: An 8-channel local B0 coil array is made to carry sinusoidal currents during signal readout to accelerate 2D Cartesian scans. An MRI sampling theory based on reproducing kernel Hilbert space is exploited to visualize the efficiency of nonlinear encoding in arbitrary sampling duration. A field calibration method using current monitors for local B0 coils and the ESPIRiT algorithm is proposed to facilitate image reconstruction. Image acceleration with various modulation field shapes, aliasing control, and distinct modulation frequencies are scrutinized to find an optimized modulation scheme. A safety evaluation is conducted. In vivo 2D Cartesian scans are accelerated by the local B0 coils. Results: For 2D Cartesian MRI, the optimal modulation field by this local B0 array converges to a nearly linear gradient field. With the field calibration technique, it accelerates the in vivo scans (i.e., proved safe) by threefold and eightfold free of visible artifacts, without and with SENSE, respectively. Conclusion: The nonlinear encoding analysis tool, the field calibration method, the safety evaluation procedures, and the in vivo reconstructed scans make significant steps to push MRI speed further with the local B0 coil array.

Details

show
hide
Language(s):
 Dates: 2023-102024-02
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.29799
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 91 (2) Sequence Number: - Start / End Page: 443 - 465 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149