English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Radiation damping at clinical field strength: Characterization and compensation in quantitative measurements

Wallstein, N., Müller, R., Pampel, A., & Möller, H. E. (2024). Radiation damping at clinical field strength: Characterization and compensation in quantitative measurements. Magnetic Resonance in Medicine, 91(3), 1239-1253. doi:10.1002/mrm.29934.

Item is

Files

show Files
hide Files
:
Wallstein_2023.pdf (Publisher version), 3MB
Name:
Wallstein_2023.pdf
Description:
-
OA-Status:
Hybrid
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Wallstein, Niklas1, Author           
Müller, Roland1, Author                 
Pampel, André1, Author           
Möller, Harald E.1, 2, Author           
Affiliations:
1Methods and Development Group Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              
2Felix Bloch Institute for Solid State Physics, University of Leipzig, Germany, ou_persistent22              

Content

show
hide
Free keywords: Dedicated RF coils; qMRI; Radiation damping; Relaxometry; Spin-coil interaction
 Abstract: Purpose: In any MR experiment, the bulk magnetization acts on itself, caused by the induced current in the RF receiver circuit that generates an oscillating damping field. This effect, known as "radiation damping" (RD), is usually weak and, therefore, unconsidered in MRI, but can affect quantitative studies performed with dedicated coils that provide a high SNR. The current work examined RD in a setup for investigations of small tissue specimens including a quantitative characterization of the spin-coil system.

Theory and methods: A custom-made Helmholtz coil (radius and spacing 16 mm) was interfaced to a transmit-receive (Tx/Rx) switch with integrated passive feedback for modulation or suppression of RD similar to preamplifier decoupling. Pulse sequences included pulse-width arrays to demonstrate the absence/ presence of RD and difference techniques employing gradient pulses or composite RF pulses to quantify RD effects during free precession and transmission, respectively. Experiments were performed at 3T in small samples of MnCl2 solution.

Results: Significant RD effects may impact RF pulse application and evolution periods. Effective damping time constants were comparable to typical T2 * times or echo spacings in multi-echo sequences. Measurements of the phase relation showed that deviations from the commonly assumed 90° angle between the damping field and the transverse magnetization may occur.

Conclusion: Radiation damping may affect the accuracy of quantitative MR measurements performed with dedicated RF coils. Efficient mitigation can be achieved hardware-based or by appropriate consideration in the pulse sequence.

Details

show
hide
Language(s): eng - English
 Dates: 2023-10-032023-07-202023-10-242023-11-272024-03
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/mrm.29934
Other: epub 2023
PMID: 38010072
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : -
Grant ID : -
Funding program : -
Funding organization : International Max Planck Research School on Neuroscience of Communication: Function, Structure, and Plasticity (IMPRS-NeuroCom)
Project name : -
Grant ID : -
Funding program : -
Funding organization : Projekt DEAL

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: New York : Wiley-Liss
Pages: - Volume / Issue: 91 (3) Sequence Number: - Start / End Page: 1239 - 1253 Identifier: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149