  Design and performance of the camera of the Micro-channel X-ray Telescope on-board the SVOM mission

Meuris, A., Arhancet, A., Bachet, D., Ceraudo, F., Doumayrou, E., Dumaye, L., Goetschy, A., Götz, D., Horeau, B., Huynh, D.-D., Lavanant, T., Lortholary, M., Le Mer, I., Nico, F., Pinsard, F., Prieur, M., Provost, L., Renaud, D., Renault-Tinacci, N., Schneider, B., Tourrette, T., Visticot, F., Mercier, K., & Meidinger, N. (2023). Design and performance of the camera of the Micro-channel X-ray Telescope on-board the SVOM mission. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1049:. doi:10.1016/j.nima.2022.167908.

Item is

基本情報

表示: 非表示:
アイテムのパーマリンク: https://hdl.handle.net/21.11116/0000-000E-4A75-C 版のパーマリンク: https://hdl.handle.net/21.11116/0000-000E-4A76-B
資料種別: 学術論文

ファイル

表示: ファイル
非表示: ファイル
:
Design and performance of the camera of the Micro-channel X-ray Telescope on-board the SVOM mission.pdf (全文テキスト(全般)), 3MB
 
ファイルのパーマリンク:
-
ファイル名:
Design and performance of the camera of the Micro-channel X-ray Telescope on-board the SVOM mission.pdf
説明:
-
OA-Status:
閲覧制限:
非公開
MIMEタイプ / チェックサム:
application/pdf
技術的なメタデータ:
著作権日付:
-
著作権情報:
-
CCライセンス:
-

関連URL

表示:

作成者

表示:
非表示:
 作成者:
Meuris, A., 著者
Arhancet, A., 著者
Bachet, D., 著者
Ceraudo, F., 著者
Doumayrou, E., 著者
Dumaye, L., 著者
Goetschy, A., 著者
Götz, D., 著者
Horeau, B., 著者
Huynh, D.-D., 著者
Lavanant, T., 著者
Lortholary, M., 著者
Le Mer, I., 著者
Nico, F., 著者
Pinsard, F., 著者
Prieur, M., 著者
Provost, L., 著者
Renaud, D., 著者
Renault-Tinacci, N., 著者
Schneider, B., 著者
Tourrette, T., 著者Visticot, F., 著者Mercier, K., 著者Meidinger, N.1, 著者            全て表示
所属:
1High Energy Astrophysics, MPI for Extraterrestrial Physics, Max Planck Society, ou_159890              

内容説明

表示:
非表示:
キーワード: -
 要旨: The Microchannel X-ray Telescope (MXT) is part of the scientific payload of the SVOM Sino-French space mission to observe the early afterglow of gamma-ray bursts in the 0.2–10 keV energy range and localize them within 2 arcmin. For a total mass of 42 kg and a total power of 60 W, this instrument is composed of an optical system, a structural carbon fiber tube, a radiator, a camera and a data processing unit. The camera consists of a focal plane assembly with a detector ceramic board and thermoelectric coolers, a front-end electronics, a calibration wheel and a support structure. Spectral characterization tests of the focal plane assembly based on a 256 × 256 pixel pnCCD spectroscopic imager were performed in the laboratory, at the Metrology beamline of the SOLEIL synchrotron and at the PANTER X-ray facility. Energy resolution of 79 eV FWHM at 1.5 keV was demonstrated in the nominal flight configuration (−65 °C, real time event selection by the camera). The paper presents the design, the realization and the performance of the flight camera of MXT. It focuses on the technical challenges, the original implemented solutions and the custom-made setups for the validation tests.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2023-04
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): DOI: 10.1016/j.nima.2022.167908
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  出版物の別名 : Nucl. Instrum. Methods Phys. Res. Sect. A-Accel. Spectrom. Dect. Assoc. Equip.
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: -
ページ: - 巻号: 1049 通巻号: 167908 開始・終了ページ: - 識別子(ISBN, ISSN, DOIなど): ISSN: 0168-9002