Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  GAUSS-EM, guided accumulation of ultrathin serial sections with a static magnetic field for volume electron microscopy

Fulton, K. A., Watkins, P., & Briggman, K. L. (2024). GAUSS-EM, guided accumulation of ultrathin serial sections with a static magnetic field for volume electron microscopy. Cell Reports Methods, 4(3): 100720. doi:10.1016/j.crmeth.2024.100720.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Dateien

einblenden: Dateien
ausblenden: Dateien
:
1-s2.0-S2667237524000353-main.pdf (Verlagsversion), 7MB
Name:
1-s2.0-S2667237524000353-main.pdf
Beschreibung:
-
OA-Status:
Gold
Sichtbarkeit:
Öffentlich
MIME-Typ / Prüfsumme:
application/pdf / [MD5]
Technische Metadaten:
Copyright Datum:
2024
Copyright Info:
© 2024 The Author(s).

Externe Referenzen

einblenden:
ausblenden:
Beschreibung:
-
OA-Status:
Gold
Beschreibung:
DOI: https://doi.org/10.1101/2023.11.13.566828
OA-Status:
Grün

Urheber

einblenden:
ausblenden:
 Urheber:
Fulton, Kara Ann1, Autor                 
Watkins, Paul2, Autor                 
Briggman, Kevin L.2, Autor                 
Affiliations:
1Department of Computational Neuroethology, Center of Advanced European Studies and Research (caesar), Max Planck Society, ou_3034882              
2Department of Computational Neuroethology, Max Planck Institute for Neurobiology of Behavior – caesar, Max Planck Society, ou_3361762              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Serial sectioning electron microscopy (EM) of millimeter-scale three-dimensional (3D) anatomical volumes requires the collection of thousands of ultrathin sections. Here, we report a high-throughput automated approach, GAUSS-EM (guided accumulation of ultrathin serial sections-EM), utilizing a static magnetic field to collect and densely pack thousands of sections onto individual silicon wafers. The method is capable of sectioning hundreds of microns of tissue per day at section thicknesses down to 35 nm. Relative to other automated volume EM approaches, GAUSS-EM democratizes the ability to collect large 3D EM volumes because it is simple and inexpensive to implement. We present two exemplar EM volumes of a zebrafish eye and mouse olfactory bulb collected with the method.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2024-03-25
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: Expertenbegutachtung
 Identifikatoren: DOI: 10.1016/j.crmeth.2024.100720
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Cell Reports Methods
  Kurztitel : Cell Rep Methods
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: Amsterdam, The Netherlands : Elsevier
Seiten: - Band / Heft: 4 (3) Artikelnummer: 100720 Start- / Endseite: - Identifikator: Anderer: ISSN
CoNE: https://pure.mpg.de/cone/journals/resource/2667-2375