English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Comprehensive 7 T CEST: A clinical MRI protocol covering multiple exchange rate regimes

Fabian, M., Rajput, J., Schüre, J.-R., Weinmüller, S., Mennecke, A., Möhle, T., et al. (2024). Comprehensive 7 T CEST: A clinical MRI protocol covering multiple exchange rate regimes. NMR in Biomedicine, 37(5): e5096. doi:10.1002/nbm.5096.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
Fabian, MS, Author
Rajput, JR, Author
Schüre, J-R, Author
Weinmüller, S, Author
Mennecke , A, Author
Möhle, TA, Author
Rampp, S, Author
Schmidt, M, Author
Dörfler, A, Author
Zaiss, M1, Author                 
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Chemical exchange saturation transfer (CEST) is a magnetic resonance (MR) imaging method providing molecular image contrasts based on indirect detection of low concentrated solutes. Previous CEST studies focused predominantly on the imaging of single CEST exchange regimes (e.g., slow, intermediate or fast exchanging groups). In this work, we aim to establish a so-called comprehensive CEST protocol for 7 T, covering the different exchange regimes by three saturation B1 amplitude regimes: low, intermediate and high. We used the results of previous publications and our own simulations in pulseq-CEST to produce a 7 T CEST protocol that has sensitivity to these three B1 regimes. With postprocessing optimization (simultaneous mapping of water shift and B1, B0-fitting, multiple interleaved mode saturation B1 correction, neural network employment (deepCEST) and analytical input feature reduction), we are able to shorten our initially 40 min protocol to 15 min and generate six CEST contrast maps simultaneously. With this protocol, we measured four healthy subjects and one patient with a brain tumor. We established a comprehensive CEST protocol for clinical 7 T MRI, covering three different B1 amplitude regimes. We were able to reduce the acquisition time significantly by more than 50%, while still maintaining decent image quality and contrast in healthy subjects and one patient with a tumor. Our protocol paves the way to perform comprehensive CEST studies in clinical scan times for hypothesis generation regarding molecular properties of certain pathologies, for example, ischemic stroke or high-grade brain tumours.

Details

show
hide
Language(s):
 Dates: 2024-022024-05
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1002/nbm.5096
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: NMR in Biomedicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: London : Heyden & Son
Pages: 12 Volume / Issue: 37 (5) Sequence Number: e5096 Start / End Page: - Identifier: ISSN: 0952-3480
CoNE: https://pure.mpg.de/cone/journals/resource/954925574973