  In-flight radiometric calibration of the Metis Visible Light channel using stars and comparison with STEREO-A/COR2 data

De Leo, Y., Burtovoi, A., Teriaca, L., Romoli, M., Chioetto, P., Andretta, V., et al. (2023). In-flight radiometric calibration of the Metis Visible Light channel using stars and comparison with STEREO-A/COR2 data. Astronomy and Astrophysics, 676, A45. doi:10.1051/0004-6361/202345979.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Not specified

Creators

show
hide
 Creators:
De Leo, Y.1, Author           
Burtovoi, A., Author
Teriaca, L.1, Author           
Romoli, M., Author
Chioetto, P., Author
Andretta, V., Author
Uslenghi, M., Author
Landini, F., Author
Susino, R., Author
Pancrazzi, M., Author
Frassati, F., Author
Giarrusso, M., Author
Giordano, S., Author
Zangrilli, L., Author
Spadaro, D., Author
Abbo, L., Author
Bemporad, A., Author
Capobianco, G., Author
Capuano, G. E., Author
Casini, C., Author
Casti, M., AuthorCorso, A. J., AuthorDa Deppo, V., AuthorFabi, M., AuthorFineschi, S., AuthorFrassetto, F., AuthorGrimani, C., AuthorGuglielmino, S. L., AuthorHeinzel, P., AuthorJerse, G., AuthorLiberatore, A., AuthorMagli, E., AuthorMassone, G., AuthorMesserotti, M., AuthorMoses, J. D., AuthorNaletto, G., AuthorNicolini, G., AuthorPelizzo, M. G., AuthorRomano, P., AuthorRussano, G., AuthorSasso, C., AuthorSchühle, U., AuthorStraus, T., AuthorSlemer, A., AuthorStangalini, M., AuthorTelloni, D., AuthorVolpicelli, C. A., AuthorZuppella, P., Author more..
Affiliations:
1Department Sun and Heliosphere, Max Planck Institute for Solar System Research, Max Planck Society, ou_1832289              

Content

show
hide
Free keywords: Sun: corona
 Abstract: Context. We present the results for the in-flight radiometric calibration performed for the Visible Light (VL) channel of the Metis coronagraph on board Solar Orbiter.
Aims: The radiometric calibration is a fundamental step in building the official pipeline of the instrument, devoted to producing the calibrated data in physical units (L2 data).
Methods: To obtain the radiometric calibration factor (ϵVL), we used stellar targets transiting the Metis field of view. We derived ϵVLby determining the signal of each calibration star by means of the aperture photometry and calculating its expected flux in the Metis band pass. The analyzed data set covers the time range from the beginning of the Cruise Phase of the mission (June 2020) until March 2021.
Results: Considering the uncertainties, the estimated factor ϵVLis in a good agreement with that obtained during the on-ground calibration campaign. This implies that up to March 2021 there was no measurable reduction in the VL channel throughput. Finally, we compared the total and polarized brightness visible light images of the solar corona acquired with Metis and STEREO-A/COR2 during the November 2020 superior conjunction of these instruments. A general good agreement was obtained between the images of these instruments for both the total and polarized brightness.

Details

show
hide
Language(s):
 Dates: 2023
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1051/0004-6361/202345979
ISSN: 0004-6361
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Astronomy and Astrophysics
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 676 Sequence Number: - Start / End Page: A45 Identifier: -