English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  In vivo low-dose phase-contrast CT for quantification of functional and anatomical alterations in lungs of an experimental allergic airway disease mouse model

Dullin, C., Albers, J., Tagat, A., Lorenzon, A., D'Amico, L., Chiriotti, S., et al. (2024). In vivo low-dose phase-contrast CT for quantification of functional and anatomical alterations in lungs of an experimental allergic airway disease mouse model. Frontiers in medicine, 11: 1338846. doi:10.3389/fmed.2024.1338846.

Item is

Files

show Files
hide Files
:
fmed-11-1338846.pdf (Publisher version), 4MB
Name:
fmed-11-1338846.pdf
Description:
-
OA-Status:
Gold
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-

Locators

show

Creators

show
hide
 Creators:
Dullin, Christian1, Author           
Albers , Jonas, Author
Tagat, Aishwarya, Author
Lorenzon, Andrea, Author
D'Amico, Lorenzo, Author
Chiriotti, Sabina, Author
Sodini, Nicola, Author
Dreossi, Diego, Author
Alves, Frauke1, Author           
Bergamaschi, Anna, Author
Tromba, Giuliana, Author
Affiliations:
1Research Group of Translational Molecular Imaging, Max Planck Institute for Multidisciplinary Sciences, Max Planck Society, ou_3350306              

Content

show
hide
Free keywords: -
 Abstract: Introduction:
Synchrotron-based propagation-based imaging (PBI) is ideally suited for lung imaging and has successfully been applied in a variety of in vivo small animal studies. Virtually all these experiments were tailored to achieve extremely high spatial resolution close to the alveolar level while delivering high x-ray doses that would not permit longitudinal studies. However, the main rationale for performing lung imaging studies in vivo in small animal models is the ability to follow disease progression or monitor treatment response in the same animal over time. Thus, an in vivo imaging strategy should ideally allow performing longitudinal studies.

Methods:
Here, we demonstrate our findings of using PBI-based planar and CT imaging with two different detectors—MÖNCH 0.3 direct conversion detector and a complementary metal-oxide-semiconductor (CMOS) detector (Photonics Science)—in an Ovalbumin induced experimental allergic airway disease mouse model in comparison with healthy controls. The mice were imaged free breathing under isoflurane anesthesia.

Results:
At x-ray dose levels below those once used by commercial small animal CT devices at similar spatial resolutions, we were able to resolve structural changes at a pixel size down to 25 μm and demonstrate the reduction in elastic recoil in the asthmatic mice in cinematic planar x-ray imaging with a frame rate of up to 100 fps.

Discussion:
Thus, we believe that our approach will permit longitudinal small animal lung disease studies, closely following the mice over longer time spans.

Details

show
hide
Language(s): eng - English
 Dates: 2024-02-12
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.3389/fmed.2024.1338846
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : --
Grant ID : -
Funding program : -
Funding organization : -

Source 1

show
hide
Title: Frontiers in medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Lausanne : Frontiers Media
Pages: - Volume / Issue: 11 Sequence Number: 1338846 Start / End Page: - Identifier: ISSN: 2296-858X
CoNE: https://pure.mpg.de/cone/journals/resource/2296-858X