  Test-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord

Lebret, A., Lévy, S., Freund, P., Callot, V., & Seif, M. (2024). Test-retest repeatability of intravoxel incoherent motion (IVIM) measurements in the cervical cord. medRxiv. doi:10.1101/2024.04.06.24305341.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Green

Creators

show
hide
 Creators:
Lebret, Anna, Author
Lévy, Simon, Author
Freund, Patrick1, Author                 
Callot, Virginie, Author
Seif, Maryam1, Author           
Affiliations:
1Department Neurophysics (Weiskopf), MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_2205649              

Content

show
hide
Free keywords: -
 Abstract: This work aimed at assessing the reliability of intravoxel incoherent motion (IVIM) parameters sensitive to perfusion changes in the cervical cord by determining the test-retest variability across subjects and different post-processing fitting algorithms. IVIM test-retest scans were acquired in the cervical cord (C1-C3) of 10 healthy subjects on a 3T MRI scanner, with a 15-minute break in-between. IVIM parameters, including microvascular volume fraction (F), pseudo-diffusion coefficient (D*), blood flow-related coefficient (F · D*), and diffusion coefficient (D), were derived using voxel-wise and region of interest (ROI)-wise fits. The reliability of each IVIM parameter was determined with coefficients of variation (CV), intraclass correlation coefficients (ICC), Bland-Altman analysis and linear regression. To assess the effects of the different fitting approaches, a two-way repeated-measures analysis of variance (ANOVA) was conducted on the CVs calculated across fitting algorithms. Mean CVs of IVIM parameters calculated across subjects using the voxel-wise fit was lower in the white matter (WM) and grey matter (GM) (2.6% to 15.6%; 2.2% to 16.4%, respectively) compared with those calculated using the ROI-wise fit approach (WM: 4.5%-32.2%; GM: 3.4%-53.4%). The voxel-wise fit in the WM yielded higher ICC values (good-to-excellent, 0.71 – 0.97) compared to the ROI-wise fit approach (0.49 – 0.90). IVIM parameters, derived using the voxel-wise fitting approach, demonstrated a high reliability in the cervical cord. Robust IVIM metrics, observed across scans and subjects, can facilitate studies targeting perfusion impairment and pave the way to future clinical trials assessing perfusion impairment as a potential quantitative biomarker.

Details

show
hide
Language(s): eng - English
 Dates: 2024-04-07
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1101/2024.04.06.24305341
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: medRxiv
Source Genre: Web Page
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: - Identifier: -