  MR imaging of the magnetic fields induced by injected currents can guide improvements of individualized head volume conductor models

Gregersen, F., Eroğlu, H., Göksu, C., Puonti, O., Zuo, Z., Thielscher, A., et al. (2024). MR imaging of the magnetic fields induced by injected currents can guide improvements of individualized head volume conductor models. Imaging Neuroscience, Epub ahead. doi:10.1162/imag_a_00176.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Gregersen, F, Author
Eroğlu, HH, Author
Göksu, C1, Author                 
Puonti, O, Author
Zuo, Z, Author
Thielscher, A, Author                 
Hanson, LG, Author
Affiliations:
1Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society, ou_1497796              

Content

show
hide
Free keywords: -
 Abstract: Volume conductor models of the human head are routinely used to estimate the induced electric fields in transcranial brain stimulation (TBS) and for source localization in electro- and magnetoencephalography (EEG and MEG). Magnetic resonance current density imaging (MRCDI) has the potential to act as a non-invasive method for dose control and model validation but requires very sensitive MRI acquisition approaches.
A double-echo echo-planar imaging (EPI) method is here introduced. It combines fast and sensitive imaging of the magnetic fields generated by the current flow of transcranial electric stimulation with increased robustness to physiological noise. For validation, noise floor measurements without injected currents were obtained in 5 subjects for an established multi-echo gradient-echo (MGRE) sequence and the new EPI method. In addition, data with current injection was acquired in each subject with a right-left (RL) and anterior-posterior (AP) electrode montage with both sequences to assess the accuracy of subject-specific detailed head models.
In line with previous findings, the noise floor measurements showed that the MGRE results suffered from spatial low-frequency noise patterns, which were mostly absent in the EPI data. A recently published approach optimizes the ohmic conductivities of subject-specific head models by minimizing the difference between simulated and measured current-induced magnetic fields. Here, simulations demonstrated that the MGRE noise patterns have a larger negative impact on the optimization results than the EPI noise. For the current injection measurements, a larger discrepancy was found for the RL electrode montage compared with the AP electrode montage consistently for all subjects. This discrepancy remained in part also after optimization of the ohmic conductivities, was similar for the data of the two sequences and larger than the measurement noise and thus demonstrates systematic biases in the volume conductor models.
We have shown that EPI-based MRCDI is superior to established techniques by mitigating the effects of previously reported spatial low-frequency noise in MRCDI if limited spatial resolution is acceptable. Additionally, the consistent inter-subject results indicate that MRCDI is capable of picking up inaccuracies in computational head models and will be useful to guide systematic improvements.

Details

show
hide
Language(s):
 Dates: 2024-04
 Publication Status: Published online
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1162/imag_a_00176
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Imaging Neuroscience
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Cambridge, MA, USA : MIT Press
Pages: - Volume / Issue: Epub ahead Sequence Number: - Start / End Page: - Identifier: ISSN: 2837-6056
CoNE: https://pure.mpg.de/cone/journals/resource/2837-6056