English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  Effect of inspiration on airway dimensions measured in maximal inspiration CT images of subjects without airflow limitation

Petersen, J., Wille, M., Raket, L., Feragen, A., Pedersen, J., Nielsen, M., et al. (2014). Effect of inspiration on airway dimensions measured in maximal inspiration CT images of subjects without airflow limitation. European Radiology, 24(9), 2319-2325. doi:10.1007/s00330-014-3261-3.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Petersen, J, Author
Wille, MMW, Author
Raket, LL, Author
Feragen, A1, Author                 
Pedersen, JH, Author
Nielsen, M, Author
Dirksen, A, Author
de Bruijne, M, Author
Affiliations:
1Department Molecular Biology, Max Planck Institute for Developmental Biology, Max Planck Society, ou_3375790              

Content

show
hide
Free keywords: -
 Abstract: Objectives: To study the effect of inspiration on airway dimensions measured in voluntary inspiration breath-hold examinations.
Methods: 961 subjects with normal spirometry were selected from the Danish Lung Cancer Screening Trial. Subjects were examined annually for five years with low-dose CT. Automated software was utilized to segment lungs and airways, identify segmental bronchi, and match airway branches in all images of the same subject. Inspiration level was defined as segmented total lung volume (TLV) divided by predicted total lung capacity (pTLC). Mixed-effects models were used to predict relative change in lumen diameter (ALD) and wall thickness (AWT) in airways of generation 0 (trachea) to 7 and segmental bronchi (R1-R10 and L1-L10) from relative changes in inspiration level.
Results: Relative changes in ALD were related to relative changes in TLV/pTLC, and this distensibility increased with generation (p < 0.001). Relative changes in AWT were inversely related to relative changes in TLV/pTLC in generation 3--7 (p < 0.001). Segmental bronchi were widely dispersed in terms of ALD (5.7 ± 0.7 mm), AWT (0.86 ± 0.07 mm), and distensibility (23.5 ± 7.7%).
Conclusions: Subjects who inspire more deeply prior to imaging have larger ALD and smaller AWT. This effect is more pronounced in higher-generation airways. Therefore, adjustment of inspiration level is necessary to accurately assess airway dimensions.

Details

show
hide
Language(s):
 Dates: 2014-09
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: DOI: 10.1007/s00330-014-3261-3
PMID: 24903230
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: European Radiology
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Berlin - Heidelberg : Springer
Pages: - Volume / Issue: 24 (9) Sequence Number: - Start / End Page: 2319 - 2325 Identifier: ISSN: 0938-7994
ISSN: 1432-1084