  Two-dimensional spatially-selective RF excitation pulses in echo-planar Imaging

Rieseberg, S., Frahm, J., & Finsterbusch, F. (2002). Two-dimensional spatially-selective RF excitation pulses in echo-planar Imaging. Magnetic Resonance in Medicine, 47(6), 1186-1193. Retrieved from http://onlinelibrary.wiley.com/doi/10.1002/mrm.10157/pdf.

Item is

Files

show Files
hide Files
:
599613.pdf (Publisher version), 2MB
Name:
599613.pdf
Description:
-
OA-Status:
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

show
hide
 Creators:
Rieseberg, S.1, Author           
Frahm, J.1, Author           
Finsterbusch, F., Author
Affiliations:
1Biomedical NMR Research GmbH, MPI for biophysical chemistry, Max Planck Society, ou_578634              

Content

show
hide
Free keywords: magnetic resonance imaging; zoom imaging; localized imaging; 2D-selective RF excitation; echo-planar imaging
 Abstract: Two-dimensional spatially-selective RF (2DRF) excitation pulses were developed for single-shot echo-planar imaging (EPI) with reduced field of view (FOV) in the phase-encoding direction. The decreased number of k-space lines significantly shortens the length of the EPI echo train. Thus, both gradient-echo and spin-echo 2DRF-EPI images of the human brain at 2.0 T exhibit markedly reduced susceptibility artifacts in regions close to major air cavities. Based on a blipped-planar trajectory, implementation of a typical 2DRF pulse resulted in a 26-ms pulse duration, a 5-mm section thickness, a 40-mm FOV along the phase-encoding direction, and a 200-mm distance of the unavoidable side excitations from the center of the FOV. For the above conditions and at 2 x 2 mm(2) resolution, 2DRF-EPI yielded an echo train length of only 21 ms, as opposed to 102 ms for conventional EPI. This gain in time may be used to achieve higher spatial resolution. For example, spin-echo 2DRF- EPI of a 40-mm FOV at 1 x 1 mm(2) resolution led to an echo train of 66 ms. Although the current implementation still lacks user-friendliness, 2DRF pulses are likely to become a useful addition to the arsenal of advanced MRI tools.

Details

show
hide
Language(s): eng - English
 Dates: 2002-06
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 47 (6) Sequence Number: - Start / End Page: 1186 - 1193 Identifier: -