English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 
 
DownloadE-Mail
  A new high-aperture glycerol immersion objective lens and its application to 3D-fluorescence microscopy

Martini, N., Bewersdorf, J., & Hell, S. W. (2002). A new high-aperture glycerol immersion objective lens and its application to 3D-fluorescence microscopy. Journal of Microscopy, 206, 146-151. Retrieved from http://onlinelibrary.wiley.com/doi/10.1046/j.1365-2818.2002.01016.x/pdf.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Martini, N.1, Author           
Bewersdorf, J.1, Author           
Hell, S. W.1, Author           
Affiliations:
1Department of NanoBiophotonics, MPI for biophysical chemistry, Max Planck Society, ou_578627              

Content

show
hide
Free keywords: aberrations; confocal; fluorescence; glycerol; objective lens; refractive index mismatch; resolution
 Abstract: High-resolution light microscopy of glycerol-mounted biological specimens is performed almost exclusively with oil immersion lenses. The reason is that the index of refraction of the oil and the cover slip of similar to1.51 is close to that of similar to1.45 of the glycerol mountant, so that refractive index mismatch-induced spherical aberrations are tolerable to some extent. Here we report the application of novel cover glass-corrected glycerol immersion lenses of high numerical aperture (NA) and the avoidance of these aberrations. The new lenses feature a semi-aperture angle of 68.5degrees, which is slightly larger than that of the diffraction-limited 1.4 NA oil immersion lenses. The glycerol lenses are corrected for a quartz cover glass of 220 mum thickness and for a 80% glycerol- water immersion solution. Featuring an aberration correction collar, the lens can adapt to glycerol concentrations ranging between 72% and 88%, to slight variations of the temperature, and to the cover glass thickness. As the refractive index mismatch-induced aberrations are particularly important to quantitative confocal fluorescence microscopy, we investigated the axial sectioning ability and the axial chromatic aberrations in such a microscope as well as the image brightness as a function of the penetration depth. Whereas there is a significant decrease in image brightness associated with oil immersion, this decrease is absent with the glycerol immersion system. In addition, we show directly the compression of the optic axis in the case of oil immersion and its absence in the glycerol system. The unique advantages of these new lenses in high-resolution microscopy with two coherently used opposing lenses, such as 4 Pi-microscopy, are discusse

Details

show
hide
Language(s): eng - English
 Dates: 2002-05-02
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: Journal of Microscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 206 Sequence Number: - Start / End Page: 146 - 151 Identifier: -