English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
EndNote (UTF-8)
 
DownloadE-Mail
  Fast scanning and efficient photodetection in a simple two-photon microscope.

Tan, Y. P., Llano, I., Hopt, A., Wuerriehausen, F., & Neher, E. (1999). Fast scanning and efficient photodetection in a simple two-photon microscope. Journal of Neuroscience Methods, 92(1-2), 123-135. doi:10.1016/S0165-0270(99)00103-X.

Item is

Files

hide Files
:
600669.pdf (Publisher version), 2MB
 
File Permalink:
-
Name:
600669.pdf
Description:
-
OA-Status:
Visibility:
Restricted ( Max Planck Society (every institute); )
MIME-Type / Checksum:
application/pdf
Technical Metadata:
Copyright Date:
-
Copyright Info:
-
License:
-

Locators

show

Creators

hide
 Creators:
Tan, Y. P.1, Author           
Llano, I.1, Author           
Hopt, A.2, Author           
Wuerriehausen, F.2, Author           
Neher, E.2, Author           
Affiliations:
1Research Group of Cellular Neurobiology, MPI for biophysical chemistry, Max Planck Society, ou_578560              
2Department of Membrane Biophysics, MPI for biophysical chemistry, Max Planck Society, ou_578579              

Content

hide
Free keywords: -
 Abstract: Two-photon laser scan microscopy carries many advantages for work on brain slices and bulk tissue. However, it has very low signal levels compared to conventional fluorescence microscopy. This is disadvantageous in fast imaging applications when photon shot noise is limiting. Working on brain slices with excitation powers of 8–10 mW at the specimen plane, the resting signal from cerebellar Purkinje cell somas loaded with 10 μM Oregon Green 488 BAPTA-1 averaged 4 detected photons/μs; axons of interneurons loaded with 200 μM of this indicator yielded about 1 photon/μs. To obtain satisfactory images at high time resolution, long pixel dwell times are required and data collection should be restricted to as few pixels as necessary. Furthermore, a large proportion of total measurement time (duty cycle) should be available for data collection. We therefore developed a method for scanning small regions of interest with line repetition rates two to four times higher than conventional ones and a duty cycle of 70%. We also compared the performance of several photodetectors and found the optimum choice to depend strongly on the photon flux during a given application. For fluxes smaller than 5 photons/μs, the photon counting avalanche photodiode shows the best signal to noise ratio. At larger fluxes, photomultipliers or intensified photodiodes are superior.

Details

hide
Language(s): eng - English
 Dates: 1999-10
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: DOI: 10.1016/S0165-0270(99)00103-X
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

hide
Title: Journal of Neuroscience Methods
  Other : J. Neurosci. Meth.
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: Amsterdam : Elsevier
Pages: - Volume / Issue: 92 (1-2) Sequence Number: - Start / End Page: 123 - 135 Identifier: ISSN: 0165-0270
CoNE: https://pure.mpg.de/cone/journals/resource/954925480594