日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Functional contrast based on intermolecular double-quantum coherences: Influence of the correlation distance

Schäfer, A., & Möller, H. E. (2007). Functional contrast based on intermolecular double-quantum coherences: Influence of the correlation distance. Magnetic Resonance in Medicine, 58(4), 696-704. doi:10.1002/mrm.21406.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Green

作成者

表示:
非表示:
 作成者:
Schäfer, Andreas1, 著者           
Möller, Harald E.1, 著者           
所属:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

内容説明

表示:
非表示:
キーワード: BOLD contrast; Correlation distance; Distant dipolar field; Intermolecular double-quantum coherence (iDQC)
 要旨: A functional MRI (fMRI) study with visual stimulation of healthy subjects was performed at 3T exploiting intermolecular double-quantum coherences. The correlation distance, dc, was varied between 60 and 300 μm for different evolution times, τ. Robust activation was obtained in all experiments with average signal changes (ΔS2) = 8.4 ± 0.7% and 9.4 ± 0.8% for τ = 15 and 20 ms, respectively) exceeding those normally associated with conventional blood oxygen level-dependent (BOLD) fMRI. Relaxation-rate changes (ΔR2 = 0.33 ± 0.36 s -1 and ΔR2* = 0.77 ± 0.54 s -1) were similar to those commonly obtained for the extravascular BOLD effect. The number of activated voxels increased with increasing d c until a plateau was reached at ≈120 μm. Similar trends were observed for the activation-induced percent signal change and for the maximal Z-scores. These effects were quantitatively explained by a reduced sensitivity at short dc due to increasing signal attenuation related to diffusion and an increasing amount of signal fluctuations in the fMRI time series due to imperfect suppression of unwanted coherence pathways. Consistent indications of a preferential selection of susceptibility changes in blood vessels of a particular size were not obtained. © 2007 Wiley-Liss, Inc.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2007-03-162007-08-062007-09-262007-10
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 345794
DOI: 10.1002/mrm.21406
PMID: 17899607
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Magnetic Resonance in Medicine
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: [Hoboken, NJ] : Wiley
ページ: - 巻号: 58 (4) 通巻号: - 開始・終了ページ: 696 - 704 識別子(ISBN, ISSN, DOIなど): ISSN: 0740-3194