Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

 
 
DownloadE-Mail
  Identifying systematic errors in quantitative dynamic-susceptibility contrast perfusion imaging by high-resolution multi-echo parallel EPI

Jochimsen, T. H., Newbould, R. D., Skare, S. T., Clayton, D. B., Albers, G. W., Moseley, M. E., et al. (2007). Identifying systematic errors in quantitative dynamic-susceptibility contrast perfusion imaging by high-resolution multi-echo parallel EPI. NMR in Biomedicine, 20(4), 429-438. doi:10.1002/nbm.1107.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3985853/ (beliebiger Volltext)
Beschreibung:
-
OA-Status:
Grün

Urheber

einblenden:
ausblenden:
 Urheber:
Jochimsen, Thies H.1, Autor           
Newbould, Rexford D., Autor
Skare, Stefan T., Autor
Clayton, David B., Autor
Albers, Gregory W., Autor
Moseley, Michael E., Autor
Bammer, Roland, Autor
Affiliations:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Inhalt

einblenden:
ausblenden:
Schlagwörter: Arterial input function; Parallel imaging; Quantitative perfusion-weighted imaging; Transverse relaxation
 Zusammenfassung: Several obstacles usually confound a straightforward perfusion analysis using dynamic-susceptibility contrast-based magnetic resonance imaging (DSC-MRI). In this work, it became possible to eliminate some of these sources of error by combining a multiple gradient-echo technique with parallel imaging (PI): first, the large dynamic range of tracer concentrations could be covered satisfactorily with multiple echo times (TE) which would otherwise result in overestimation of image magnitude in the presence of noise. Second, any bias from T1 relaxation could be avoided by fitting to the signal magnitude of multiple TEs. Finally, with PI, a good tradeoff can be achieved between number of echoes, brain coverage, temporal resolution and spatial resolution. The latter reduces partial voluming, which could distort calculation of the arterial input function. Having ruled out these sources of error, a 4-fold overestimation of cerebral blood volume and flow remained, which was most likely due to the completely different relaxation mechanisms that are effective in arterial voxels compared with tissue. Hence, the uniform tissue-independent linear dependency of relaxation rate upon tracer concentration, which is usually assumed, must be questioned. Therefore, DSC-MRI requires knowledge of the exact dependency of transverse relaxation rate upon tracer concentration in order to calculate truly quantitative perfusion maps. Copyright © 2006 John Wiley & Sons, Ltd.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2006-05-232006-08-282006-10-172007-04-24
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 345782
Anderer: P8268
DOI: 10.1002/nbm.1107
PMC: PMC3985853
PMID: 17044140
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden: ausblenden:
Projektname : -
Grant ID : RO1NS047607, RO1EB002711, RO1NS039325
Förderprogramm : -
Förderorganisation : National Institute of Health (NIH)

Quelle 1

einblenden:
ausblenden:
Titel: NMR in Biomedicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: [Hoboken, NJ] : Wiley
Seiten: - Band / Heft: 20 (4) Artikelnummer: - Start- / Endseite: 429 - 438 Identifikator: ISSN: 0952-3480