Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Measurements of hyperpolarized gas properties in the lung. Part III: 3He T1

Möller, H. E., Hedlund, L. W., Chen, X. J., Carey, M. R., Chawla, M. S., Wheeler, C. T., et al. (2001). Measurements of hyperpolarized gas properties in the lung. Part III: 3He T1. Magnetic Resonance in Medicine, 45(3), 421-430. doi:10.1002/1522-2594(200103)45:3<421:AID-MRM1055>3.0.CO;2-K.

Item is

Externe Referenzen

einblenden:

Urheber

einblenden:
ausblenden:
 Urheber:
Möller, Harald E.1, Autor           
Hedlund, Laurence W., Autor
Chen, X. J., Autor
Carey, Michael R., Autor
Chawla, Mark S., Autor
Wheeler, C. Theodore, Autor
Johnson, G. Allan, Autor
Affiliations:
1MPI of Cognitive Neuroscience (Leipzig, -2003), The Prior Institutes, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634574              

Inhalt

einblenden:
ausblenden:
Schlagwörter: -
 Zusammenfassung: Hyperpolarized 3He spin-lattice relaxation was investigated in the guinea pig lung using spectroscopy and imaging techniques with a repetitive RF pulse series. T1 was dominated by interactions with oxygen and was used to measure the alveolar O2 partial pressure. In animals ventilated with a mixture of 79% 3He and 21% O2, T1 dropped from 19.6 sec in vivo to 14.6 sec after cardiac arrest, reflecting the termination of the intrapulmonary gas exchange. The initial difference in oxygen concentration between inspired and alveolar air, and the temporal decay during apnea were related to functional parameters. Estimates of oxygen uptake were 29 ± 11 mL min−1 kg−1 under normoxic conditions, and 9.0 ± 2.0 mL min−1 kg−1 under hypoxic conditions. Cardiac output was estimated to be 400 ± 160 mL min−1 kg−1. The functional residual capacity derived from spirometric magnetic resonance experiments varied with body mass between 5.4 ± 0.3 mL and 10.7 ± 1.1 mL. Magn Reson Med 45:421–430, 2001.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2001
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 394146
DOI: 10.1002/1522-2594(200103)45:3<421::AID-MRM1055>3.0.CO;2-K
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden:

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: New York : Wiley-Liss
Seiten: - Band / Heft: 45 (3) Artikelnummer: - Start- / Endseite: 421 - 430 Identifikator: ISSN: 0740-3194
CoNE: https://pure.mpg.de/cone/journals/resource/954925538149