English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
 PreviousNext  
  Perfusion mapping with multiecho multishot parallel imaging EPI

Newbould, R. D., Skare, S. T., Jochimsen, T. H., Alley, M. T., Moseley, M. E., Albers, G. W., et al. (2007). Perfusion mapping with multiecho multishot parallel imaging EPI. Magnetic Resonance in Medicine, 58(1), 70-81. doi:10.1002/mrm.21255.

Item is

Files

show Files

Locators

show
hide
Description:
-
OA-Status:
Green

Creators

show
hide
 Creators:
Newbould, Rexford D., Author
Skare, Stefan T., Author
Jochimsen, Thies H.1, Author           
Alley, Marcus T., Author
Moseley, Michael E., Author
Albers, Gregory W., Author
Bammer, Roland, Author
Affiliations:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

Content

show
hide
Free keywords: Bolus tracking; Dynamic susceptibility contrast; Parallel imaging; Perfusion
 Abstract: Echo-planar imaging (EPI) is the standard technique for dynamic susceptibility-contrast (DSC) perfusion MRI. However, EPI suffers from well-known geometric distortions, which can be reduced by increasing the k-space phase velocity. Moreover, the long echo times (TEs) used in DSC lead to signal saturation of the arterial input signal, and hence to severe quantitation errors in the hemodynamic information. Here, through the use of interleaved shot acquisition and parallel imaging (PI), rapid volumetric EPI is performed using pseudo-single-shot (ss)EPI with the effective T2* blur and susceptibility distortions of a multishot EPI sequence. The reduced readout lengths permit multiple echoes to be acquired with temporal resolution and spatial coverage similar to those obtained with a single-echo method. Multiecho readouts allow for unbiased R2* mapping to avoid incorrect estimation of tracer concentration due to signal saturation or T1 shortening effects. Multiecho perfusion measurement also mitigates the signal-to-noise ratio (SNR) reduction that results from utilizing PI. Results from both volunteers and clinical stroke patients are presented. This acquisition scheme can aid most rapid time-series acquisitions. The use of this method for DSC addresses the problem of signal saturation and T1 contamination while it improves image quality, and is a logical step toward better quantitative MR PWI. © 2007 Wiley-Liss, Inc.

Details

show
hide
Language(s): eng - English
 Dates: 2006-10-212007-03-052007-07-202007-07
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 345781
Other: P8269
DOI: 10.1002/mrm.21255
PMID: 17659630
PMC: PMC3986027
 Degree: -

Event

show

Legal Case

show

Project information

show hide
Project name : -
Grant ID : -
Funding program : -
Funding organization : Lucas Foundation
Project name : -
Grant ID : -
Funding program : -
Funding organization : Oak Foundation
Project name : -
Grant ID : 1R01EB002771
Funding program : -
Funding organization : National Institutes of Health (NIH)
Project name : -
Grant ID : P41RR09784
Funding program : -
Funding organization : Center of Advanced MR Technology at Stanford

Source 1

show
hide
Title: Magnetic Resonance in Medicine
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: [Hoboken, NJ] : Wiley
Pages: - Volume / Issue: 58 (1) Sequence Number: - Start / End Page: 70 - 81 Identifier: ISSN: 0740-3194