Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT
  Reconstruction of undersampled non-cartesian data sets using pseudo-cartesian GRAPPA in conjunction with GROG

Seiberlich, N., Breuer, F. A., Heidemann, R. M., Blaimer, M., Griswold, M. A., & Jakob, P. M. (2008). Reconstruction of undersampled non-cartesian data sets using pseudo-cartesian GRAPPA in conjunction with GROG. Magnetic Resonance in Medicine, 59(5), 1127-1137. doi:10.1002/mrm.21602.

Item is

Basisdaten

einblenden: ausblenden:
Genre: Zeitschriftenartikel

Externe Referenzen

einblenden:
ausblenden:
externe Referenz:
https://onlinelibrary.wiley.com/doi/10.1002/mrm.21602 (Verlagsversion)
Beschreibung:
-
OA-Status:
Grün

Urheber

einblenden:
ausblenden:
 Urheber:
Seiberlich, Nicole, Autor
Breuer, Felix A., Autor
Heidemann, Robin M.1, Autor           
Blaimer, Martin, Autor
Griswold, Mark A., Autor
Jakob, Peter M., Autor
Affiliations:
1Department Neurophysics, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634550              

Inhalt

einblenden:
ausblenden:
Schlagwörter: GRAPPA; GROG; Non-Cartesian trajectories; Parallel imaging
 Zusammenfassung: Most k-space-based parallel imaging reconstruction techniques, such as Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA), necessitate the acquisition of regularly sampled Cartesian k-space data to reconstruct a nonaliased image efficiently. However, non-Cartesian sampling schemes offer some inherent advantages to the user due to their better coverage of the center of k-space and faster acquisition times. On the other hand, these sampling schemes have the disadvantage that the points acquired generally do not lie on a grid and have complex k-space sampling patterns. Thus, the extension of Cartesian GRAPPA to non-Cartesian sequences is nontrivial. This study introduces a simple, novel method for performing Cartesian GRAPPA reconstructions on undersampled non-Cartesian k-space data gridded using GROG (GRAPPA Operator Gridding) to arrive at a nonaliased image. Because the undersampled non-Cartesian data cannot be reconstructed using a single GRAPPA kernel, several Cartesian patterns are selected for the reconstruction. This flexibility in terms of both the appearance and number of patterns allows this pseudo-Cartesian GRAPPA to be used with undersampled data sets acquired with any non-Cartesian trajectory. The successful implementation of the reconstruction algorithm using several different trajectories, including radial, rosette, spiral, one-dimensional non-Cartesian, and zig-zag trajectories, is demonstrated. © 2008 Wiley-Liss, Inc.

Details

einblenden:
ausblenden:
Sprache(n): eng - English
 Datum: 2007-06-282008-01-302008-04-212008-05
 Publikationsstatus: Erschienen
 Seiten: -
 Ort, Verlag, Ausgabe: -
 Inhaltsverzeichnis: -
 Art der Begutachtung: -
 Identifikatoren: eDoc: 392224
DOI: 10.1002/mrm.21602
PMID: 18429026
 Art des Abschluß: -

Veranstaltung

einblenden:

Entscheidung

einblenden:

Projektinformation

einblenden: ausblenden:
Projektname : -
Grant ID : JA 827/1-4
Förderprogramm : -
Förderorganisation : German Research Foundation (DFG)
Projektname : -
Grant ID : -
Förderprogramm : -
Förderorganisation : Siemens Medical Solutions

Quelle 1

einblenden:
ausblenden:
Titel: Magnetic Resonance in Medicine
Genre der Quelle: Zeitschrift
 Urheber:
Affiliations:
Ort, Verlag, Ausgabe: [Hoboken, NJ] : Wiley
Seiten: - Band / Heft: 59 (5) Artikelnummer: - Start- / Endseite: 1127 - 1137 Identifikator: ISSN: 0740-3194