日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細

  Shielded dual-loop resonator for arterial spin labeling at the neck

Hetzer, S., Mildner, T., Driesel, W., Weder, M., & Möller, H. E. (2009). Shielded dual-loop resonator for arterial spin labeling at the neck. Journal of Magnetic Resonance Imaging, 29(6), 1414-1424. doi:10.1002/jmri.21803.

Item is

基本情報

表示: 非表示:
資料種別: 学術論文

ファイル

表示: ファイル

関連URL

表示:
非表示:
説明:
-
OA-Status:
Green

作成者

表示:
非表示:
 作成者:
Hetzer, Stefan1, 著者           
Mildner, Toralf1, 著者           
Driesel, Wolfgang1, 著者           
Weder, Manfred1, 著者           
Möller, Harald E.1, 著者           
所属:
1Methods and Development Unit Nuclear Magnetic Resonance, MPI for Human Cognitive and Brain Sciences, Max Planck Society, ou_634558              

内容説明

表示:
非表示:
キーワード: Continuous arterial spin labeling; Labeling coil; Perfusion, two-coil CASL
 要旨: Purpose: To construct a dual-loop coil for continuous arterial spin labeling (CASL) at the human neck and characterize it using computer simulations and magnetic resonance experiments. Materials and Methods: The labeling coil was designed as a perpendicular pair of shielded-loop resonators made from coaxial cable to obtain balanced circular loops with minimal electrical interaction with the lossy tissue. Three different excitation modes depending on the phase shift, Δψ, of the currents driving the two circular loops were investigated including a "Maxwell mode" (Δψ = 0°; ie, opposite current directions in both loops), a "quadrature mode" (Δψ = 90°), and a "Helmholtz mode" (Δψ = 180°; ie, identical current directions in both loops). Results: Simulations of the radiofrequency field distribution indicated a high inversion efficiency at the locations of the carotid and vertebral arteries. With a 7-mm-thick polypropylene insulation, a sufficient distance from tissue was achieved to guarantee robust performance at a local specific absorption rate (SAR) well below legal safety limits. Application in healthy volunteers at 3 T yielded quantitative maps of gray matter perfusion with low intersubject variability. Conclusion: The coil permits robust labeling with low SAR and minimal sensitivity to different loading conditions. © 2009 Wiley-Liss, Inc.

資料詳細

表示:
非表示:
言語: eng - English
 日付: 2008-09-102009-04-022009-05-262009
 出版の状態: 出版
 ページ: -
 出版情報: -
 目次: -
 査読: -
 識別子(DOI, ISBNなど): eDoc: 458529
DOI: 10.1002/jmri.21803
PMID: 19472417
 学位: -

関連イベント

表示:

訴訟

表示:

Project information

表示:

出版物 1

表示:
非表示:
出版物名: Journal of Magnetic Resonance Imaging
種別: 学術雑誌
 著者・編者:
所属:
出版社, 出版地: Chicago, IL : Society for Magnetic Resonance Imaging
ページ: - 巻号: 29 (6) 通巻号: - 開始・終了ページ: 1414 - 1424 識別子(ISBN, ISSN, DOIなど): ISSN: 1053-1807
CoNE: https://pure.mpg.de/cone/journals/resource/954925594512