  Mass measurements on highly charged radioactive ions, a new approach to high precision with TITAN

Dilling, J., Baartman, R., Bricault, P., Brodeur, M., Blomeley, L., Buchinger, F., et al. (2006). Mass measurements on highly charged radioactive ions, a new approach to high precision with TITAN. ULTRA-ACCURATE MASS SPECTROMETRY AND RELATED TOPICS Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue, 198-203. doi:doi:10.1016/j.ijms.2006.01.044.

Item is

Files

show Files

Locators

show

Creators

show
hide
 Creators:
Dilling, J.1, Author           
Baartman, R.2, Author
Bricault, P.2, Author
Brodeur, M.2, Author
Blomeley, L.2, Author
Buchinger, F.2, Author
Crawford, J.2, Author
Crespo López-Urrutia, J. R.1, Author           
Delheij, P.2, Author
Froese, M.3, Author           
Gwinner, G. P.2, Author
Ke, Z.2, Author
Lee, J. K. P.2, Author
Moore, R. B.2, Author
Ryjkov, V.2, Author
Sikler, G.1, Author           
Smith, M.2, Author
Ullrich, J.1, Author           
Vaz, J.2, Author
Affiliations:
1Division Prof. Dr. Joachim H. Ullrich, MPI for Nuclear Physics, Max Planck Society, ou_904547              
2TRIUMF, 4004 Wesbrook Mall, Vancouver, B.C.,V6T 2A3, Canada Department of Physics and Astronomy, University of British Columbia, 6224 Agricultural Rd., Vancouver, B.C., V6T 1Z1, Canada Department of Physics, McGill University, 3600 Rue University, Montreal, Quebec, H3A 2T3, Canada Department of Physics and Astronomy, University of Manitoba, Winnipeg, Manitoba R3T 2N2 Canada, ou_persistent22              
3Division Prof. Dr. Klaus Blaum, MPI for Nuclear Physics, Max Planck Society, ou_904548              

Content

show
hide
Free keywords: Radioactive beams; Penning trap mass spectrometry; EBIT; Charge breeding; Cooling of highly charged ions
 Abstract: TITAN (TRIUMF's Ion Trap for Atomic and Nuclear science) is a system of multiple ion traps installed at the radioactive ion beam facility ISAC. The uniqueness of the system lies in the combination of different kinds of ion traps nowhere else available, and the coupling of this system to ISAC as a source of the most intense radioactive beams of very exotic nuclei worldwide. ISAC is now been operational for more than 5 years, and has been proven to be able to deliver a broad variety of radioactive species with unsurpassed production yields, making it the facility of choice for a next generation ion trap facility, like TITAN. The physics goals of TITAN are manifold, but the emphasis lies on the test of the Standard Model via the determination of the Vud CKM matrix element, nuclear structure and halo-nuclei investigations, and nuclear astrophysics by providing precise and accurate mass measurements.

Details

show
hide
Language(s): eng - English
 Dates: 2006-04-01
 Publication Status: Issued
 Pages: -
 Publishing info: -
 Table of Contents: -
 Rev. Type: Peer
 Identifiers: eDoc: 278169
DOI: doi:10.1016/j.ijms.2006.01.044
 Degree: -

Event

show

Legal Case

show

Project information

show

Source 1

show
hide
Title: ULTRA-ACCURATE MASS SPECTROMETRY AND RELATED TOPICS Dedicated to H.-J. Kluge on the occasion of his 65th birthday anniversary - Jürgen Kluge Special Issue
Source Genre: Issue
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: - Sequence Number: - Start / End Page: 198 - 203 Identifier: -

Source 2

show
hide
Title: International Journal of Mass Spectroscopy
Source Genre: Journal
 Creator(s):
Affiliations:
Publ. Info: -
Pages: - Volume / Issue: 251 (2-3) Sequence Number: - Start / End Page: - Identifier: -