English
 
User Manual Privacy Policy Disclaimer Contact us
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT
  Measurement of the Decay Rate of the Negative Positronium Ion

Fleischer, F. (2005). Measurement of the Decay Rate of the Negative Positronium Ion. PhD Thesis, Ruprecht-Karls Universität, Heidelberg.

Item is

Basic

show hide
Item Permalink: http://hdl.handle.net/11858/00-001M-0000-0011-88EA-0 Version Permalink: http://hdl.handle.net/11858/00-001M-0000-0011-88EB-E
Genre: Thesis

Files

show Files
hide Files
:
2005-012.pdf (Any fulltext), 3MB
Name:
2005-012.pdf
Description:
-
Visibility:
Public
MIME-Type / Checksum:
application/pdf / [MD5]
Technical Metadata:
Copyright Date:
-
Copyright Info:
eDoc_access: PUBLIC
License:
-

Locators

show

Creators

show
hide
 Creators:
Fleischer, Frank1, Author              
Affiliations:
1Prof. Dirk Schwalm, Emeriti, MPI for Nuclear Physics, Max Planck Society, ou_907546              

Content

show
hide
Free keywords: -
 Abstract: Consisting of a positron and two electrons (e+e−e−), the negative ion of positronium (Ps−) is one of the simplest three-body systems with a bound state. Its constituents are stable, point-like particles, and due to the small particle masses, it is essentially free from perturbations by strong interaction effects. Together with the rather unique mass ratio, these properties make the Ps− ion an interesting object for studying the quantum-mechanical three-body problem. Despite numerous theoretical investigations, the published experimental results are so far limited to first observation and a single decay rate measurement. With a precision of 4.3%, its error is still an order of magnitude larger than the theoretical uncertainty. In this thesis, after giving a short review of the currently available theoretical results, a new determination of the decay rate is reported. This includes an exploratory experiment along the lines of the old one and a more precise measurement using an improved detection method. In the latter one, the error has been reduced to 0.8%. Moreover, the maximum precision that can be reached with the current set-up is investigated, and the prospects for further experiments at the new high-intensity positron source NEPOMUC at the FRM II research reactor in Munich are discussed.

Details

show
hide
Language(s): eng - English
 Dates: 2005-05-24
 Publication Status: Accepted / In Press
 Pages: 131 S.
 Publishing info: Heidelberg : Ruprecht-Karls Universität
 Table of Contents: -
 Rev. Type: -
 Identifiers: eDoc: 222326
 Degree: PhD

Event

show

Legal Case

show

Project information

show

Source

show