Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Second-generation MS-based high-throughput screening system for enantioselective catalysts and biocatalysts

MPG-Autoren
/persons/resource/persons58974

Schrader,  W.
Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society;
Service Department Schrader (MS), Max-Planck-Institut für Kohlenforschung, Max Planck Society;

/persons/resource/persons58529

Eipper,  A.
Research Department Reetz, Max-Planck-Institut für Kohlenforschung, Max Planck Society;
Research Department Reetz, Max-Planck-Institut für Kohlenforschung, Max Planck Society;

/persons/resource/persons58919

Reetz,  M. T.
Research Department Reetz, Max-Planck-Institut für Kohlenforschung, Max Planck Society;
Research Department Reetz, Max-Planck-Institut für Kohlenforschung, Max Planck Society;
Research Department Reetz, Max-Planck-Institut für Kohlenforschung, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Schrader, W., Eipper, A., Pugh, D. J., & Reetz, M. T. (2002). Second-generation MS-based high-throughput screening system for enantioselective catalysts and biocatalysts. Canadian Journal of Chemistry-Revue Canadienne de Chimie, 80(6), 626-632. doi:10.1139/V02-069.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-000F-99DB-2
Zusammenfassung
A high-throughput method is described, where the enantioselectivity of approximately 10 000 catalysts or biocatalysts can be determined per day. The method is based on electrospray mass spectrometric techniques using an eight- channel multiplexed (MUX) sprayer system connected to a time- of-flight mass spectrometer. The inlet of the ion source is controlled by a stepping rotor that is continuously moving from one sprayer to the next with a recording time of 100 ms for each channel and a delay time of 50 ms, thus allowing a spectrum to be obtained from each channel every 1.2 s. One cycle, where eight samples are being sprayed in parallel, requires around 70 s, which allows a 96-well microtiter plate to be screened in 14 min. Integration of two pseudo-enantiomers (S)-glycidyl phenyl ether and (R)-D-5-glycidyl phenyl ether is necessary to quantify the enantiomeric excess (ee-value), where one enantiomer is isotopically labeled to allow easy identification of the mass spectrometric signals. Errors of similar to2% for the ee-values indicate that in addition to the significant improvement in sample throughput this is also a precise method for high-throughput screening. This second- generation assay is useful for combinatorial enantioselective transition-metal catalysis and in the directed evolution of enantioselective enzymes.