English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Conference Paper

Fluorometric depth-profiling of chlorophyll corrected for yellow substances

MPS-Authors
/persons/resource/persons56597

Beutler,  Martin
Department Ecophysiology, Max Planck Institute for Limnology, Max Planck Institute for Evolutionary Biology, Max Planck Society;

/persons/resource/persons57003

Wiltshire,  Karen Helen
Department Ecophysiology, Max Planck Institute for Limnology, Max Planck Institute for Evolutionary Biology, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Beutler, M., Wiltshire, K. H., Lüring, C., Moldaenke, C., & Lohse, D. (2002). Fluorometric depth-profiling of chlorophyll corrected for yellow substances. In G. Arzul (Ed.), Aquaculture Environment and Marine Phytoplankton (pp. 231-238). Brest: Ifremer.


Cite as: https://hdl.handle.net/11858/00-001M-0000-000F-DDC5-9
Abstract
The 'spectral groups' of algae (green, blue, brown, mixed) are each characterized by a specific composition of photosynthetic pigments, particularly relevant are: Chl a, phycocyanobilin, phycoerythrobilin, fucoxanthin, peridinin and, consequently, by a specific excitation spectrum of the Chl fluorescence. This was used in earlier approaches to determine the amount of chlorophyll and the algal group composition of phytoplankton. Yellow substances (coloured dissolved organic matter) may interfere with the measurement because of overlap in the excitation spectra with phytoplankton. In a new approach, built into a submersible instrument, we correct for the influence of yellow substances on the chlorophyll fluorescence. The newly-developed probe is a submersible fluorometer which measures the emission intensity at six characteristic wavelength ranges employing pulsed light-emitting diodes. The submersible probe transfers all data on-line to a computer or stores them in the probe (fluorescence data plus the simultaneously measured water pressure for depth determination). The six-point excitation spectra are deconvoluted on the basis of norm spectra which have been obtained by analysis of several species of each spectral group. The usage of an ultra violet (UV)-ecxitation source (370 nm LED) enables the differentiation between algal fluorescence and fluorescence of yellow substances