English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Automatic beam alignment for the modecleaner cavities of GEO 600

MPS-Authors
/persons/resource/persons40456

Grote,  Hartmut
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40460

Heinzel,  Gerhard
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Freise,  Andreas
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40453

Gossler,  Stefan
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40511

Willke,  Benno
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40475

Lück,  Harald
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons1466

Strain,  Kenneth A.
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40437

Danzmann,  Karsten
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

119940.pdf
(Publisher version), 145KB

Supplementary Material (public)
There is no public supplementary material available
Citation

Grote, H., Heinzel, G., Freise, A., Gossler, S., Willke, B., Lück, H., et al. (2004). Automatic beam alignment for the modecleaner cavities of GEO 600. Applied Optics - LPE, 43(9), 1938-1945. doi:10.1364/AO.43.001938.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0013-502E-A
Abstract
The automatic alignment system for the two suspended, triangular mode-cleaner cavities of the gravitational wave detector GEO 600 has been in continuous operation since the spring of 2001. A total of 20 angular degrees of freedom are controlled by feedback loops with almost no manual alignment having been required since installation. Error signals for the eight most important degrees of freedom are obtained with the differential wave-front sensing technique. We describe the sensing system, the control topology, and the performance of the automatic alignment system. A continuous locking stretch of more than 120 h has been achieved.