English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Conference Paper

Calibration of the dual-recycled GEO600 detector for the S3 science run

MPS-Authors
/persons/resource/persons40525

Hewitson,  Martin
Observational Relativity and Cosmology, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons20655

Babak,  Stanislav
Astrophysical Relativity, AEI-Golm, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40437

Danzmann,  Karsten
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40456

Grote,  Hartmut
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40460

Heinzel,  Gerhard
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40475

Lück,  Harald
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons20662

Papa,  Maria Alessandra
Astrophysical Relativity, AEI-Golm, MPI for Gravitational Physics, Max Planck Society;

Hough,  Jim
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

Smith,  Joshua R.
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons1466

Strain,  Kenneth A.
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

/persons/resource/persons40511

Willke,  Benno
Laser Interferometry & Gravitational Wave Astronomy, AEI-Hannover, MPI for Gravitational Physics, Max Planck Society;

External Resource
No external resources are shared
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)

197947.pdf
(Publisher version), 382KB

Supplementary Material (public)
There is no public supplementary material available
Citation

Hewitson, M., Babak, S., Balasubramanian, R., Danzmann, K., Grote, H., Heinzel, G., et al. (2004). Calibration of the dual-recycled GEO600 detector for the S3 science run. Classical and Quantum Gravity, 21(20), S1711-S1722.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0013-5182-4
Abstract
The GEO 600 interferometric gravitational detector took part in an extended coincident science run of the LIGO Scientific Collaboration (S3) that started in November 2003. GEO had recently been upgraded to be the first large-scale fully suspended dual-recycled interferometer in the world and was in the early stages of commissioning in this configuration. In order to prepare the GEO 600 data for the possible extraction of science results and for exchange between analysis groups of the gravitational wave community, the data need to be accurately calibrated. An online, time-domain calibration scheme that was initially developed to calibrate the power-recycled GEO 600 configuration, has been extended to cover the significantly more complicated case of calibrating the dual-recycled interferometer, where the optical response of the instrument is much more difficult to measure and calibrate out online. This report presents an overview of this calibration scheme as it was applied to calibrating the GEO S3 science run data. In addition, results of the calibration process are presented together with some discussion of the accuracy achieved.