Deutsch
 
Hilfe Datenschutzhinweis Impressum
  DetailsucheBrowse

Datensatz

DATENSATZ AKTIONENEXPORT

Freigegeben

Zeitschriftenartikel

Quantitative in vivo diffusion imaging of cartilage using double echo steady-state free precession

MPG-Autoren
/persons/resource/persons84187

Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

Externe Ressourcen
Es sind keine externen Ressourcen hinterlegt
Volltexte (beschränkter Zugriff)
Für Ihren IP-Bereich sind aktuell keine Volltexte freigegeben.
Volltexte (frei zugänglich)
Es sind keine frei zugänglichen Volltexte in PuRe verfügbar
Ergänzendes Material (frei zugänglich)
Es sind keine frei zugänglichen Ergänzenden Materialien verfügbar
Zitation

Bieri, O., Ganter, C., & Scheffler, K. (2012). Quantitative in vivo diffusion imaging of cartilage using double echo steady-state free precession. Magnetic Resonance in Medicine, 68(3), 720–729. doi:10.1002/mrm.23275.


Zitierlink: https://hdl.handle.net/11858/00-001M-0000-0013-B626-4
Zusammenfassung
Single-shot echo-planar imaging techniques are commonly used for diffusion-weighted imaging (DWI) but offer rather poor spatial resolution and field-of-view coverage for species with short T2. In contrast, steady-state free precession (SSFP) has shown promising results for DWI of the musculoskeletal system, but quantification is generally hampered by its prominent sensitivity on relaxation times. In this work, a new and truly diffusion-weighted (that is relaxation time independent) SSFP DWI technique is introduced using a double-echo steady-state approach. Within this framework (and this is in contrast to common SSFP DWI techniques using SSFP-Echo) both primary echo paths of nonbalanced SSFP are acquired, namely the FID and the Echo. Simulations and in vitro measurements reveal that the ratio of the Echo/FID signal ratios of two double-echo steady-state scans acquired with and without diffusion sensitizing dephasing moments provides a highly relaxation independent quantity for diffusion quantification. As a result, relaxation-independent high-resolution (0.4 × 0.4 − 0.6 × 0.6 mm2 in-plane resolution) quantitative in vivo SSFP DWI is demonstrated for human articular cartilage using diffusion-weighted double-echo steady-state scans in the knee and ankle joint at 3.0 T. The derived diffusion coefficients for cartilage (D ∼ 1.0–1.5 μm2/ms) and synovial fluid (D ∼ 2.6 μm2/ms) are in agreement with previous work.