日本語
 
Help Privacy Policy ポリシー/免責事項
  詳細検索ブラウズ

アイテム詳細


公開

学術論文

23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results

MPS-Authors
/persons/resource/persons84187

Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler,  K
Department High-Field Magnetic Resonance, Max Planck Institute for Biological Cybernetics, Max Planck Society;

External Resource
There are no locators available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Trattnig, S., Welsch GH, Juras V, Szomolanyi P, Mayerhoefer ME, Stelzeneder D, Mamisch TC, Bieri O, Scheffler, K., & Zbýn, S. (2010). 23Na MR Imaging at 7 T after Knee Matrix–associated Autologous Chondrocyte Transplantation Preliminary Results. Radiology, 257(1), 175-184. doi:10.1148/radiol.10100279.


引用: https://hdl.handle.net/11858/00-001M-0000-0013-BDAA-D
要旨
Purpose: To evaluate the feasibility of sodium 7-T magnetic resonance (MR) imaging in repaired tissue and native cartilage of patients after matrix-associated autologous chondrocyte transplantation (MACT) and compare results with delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) at 3 T. Materials and Methods: Ethical approval was provided by the local ethics committee; written informed consent was obtained from all patients. Six women and six men (mean age, 32.8 year ± 8.2 [standard deviation] and 32.3 years ± 12.7, respectively) were included. Mean time between MACT and MR was 56 months ± 28. A variable three-dimensional (3D) gradient-echo (GRE) dual–flip-angle technique was used for T1 mapping before and after contrast agent administration at 3 T. All patients were also examined at 7 T (mean delay, 70.5 days ± 80.1). A sodium 23–only transmit-receive knee coil was used with the 3D GRE sequence. A statistical analysis of variance and Pearson correlation were applied. Results: Mean signal-to-noise ratio (SNR) was 24 in native cartilage and was 16 in transplants (P < .001). Mean sodium signal intensities normalized with the reference sample were 174 ± 53 and 267 ± 42 for repaired tissue in the cartilage transplant and healthy cartilage, respectively (P < .001). Mean postcontrast T1 values were 510 msec ± 195 and 756 msec ± 188 for repaired tissue and healthy cartilage, respectively (P = .005). Mean score of MR observation of cartilage repair tissue was 75 ± 14. Association between postcontrast T1 and normalized sodium signal values showed a high Pearson correlation coefficient (R) of 0.706 (P = .001). A high correlation of R = 0.836 (P = .001) was found between ratios of normalized sodium values and ratios of T1 postcontrast values. Conclusion: With the modified 3D GRE sequence at 7 T, a sufficiently high SNR in sodium images was achieved, allowing for differentiation of repaired tissue from native cartilage after MACT. A strong correlation was found between sodium imaging and dGEMRIC in patients after MACT.