Double-reference cross-correlation algorithm for separation of the arteries and veins from 3D MRA time series

MPS-Authors
There are no MPG-Authors in the publication available
External Resource
There are no locators available
Fulltext (restricted access)
There are currently no full texts shared for your IP range.
フルテキスト (公開)
公開されているフルテキストはありません
付随資料 (公開)
There is no public supplementary material available
引用

Santini, F., Patil, S., Meckel, S., Scheffler, K., & Wetzel, S. (2008). Double-reference cross-correlation algorithm for separation of the arteries and veins from 3D MRA time series. Journal of Magnetic Resonance Imaging, 28(3), 646-654. doi:10.1002/jmri.21499.


引用: https://hdl.handle.net/11858/00-001M-0000-0013-C707-C
要旨
Purpose
To present a novel postprocessing technique for artery/vein separation and background suppression from contrast-enhanced time-resolved magnetic resonance angiography datasets in order to improve the diagnosis of vessel pathologies and arteriovenous fistulas.
Materials and Methods
Ten normal, two pathologic datasets of the brain, and one hand angiography dataset were postprocessed. Cross-correlation maps between the signal time course of every voxel in the dataset and selected arterial and venous references regions of interest (ROIs) were obtained; these maps were subsequently nonlinearly transformed to obtain two indices representing the likelihood of a voxel belonging to a vessel category. Red-green-blue (RGB) color encoding was utilized to depict synthetic arteriogram and venogram images in a single diagnostically meaningful image.
Results
The technique enabled correct visual separation of vessels on various datasets, as evaluated by two expert neuroradiologists, and also highlighted characteristics of flow in arteriovenous fistulas. A quantitative comparison with existing techniques showed better separation performance on 3 out of 10 normal datasets and higher stability to acquisition characteristics and contrast agent bolus dispersion.
Conclusion
This method can be helpful in the diagnosis of vascular diseases in subjects where bolus dispersion makes it difficult to discriminate between arteries and veins with standard methods (subtraction or correlation analysis).