English
 
Help Privacy Policy Disclaimer
  Advanced SearchBrowse

Item

ITEM ACTIONSEXPORT

Released

Journal Article

Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla

MPS-Authors
/persons/resource/persons84218

Shmuel,  A
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons83851

Chaimow,  D
Former Department MRZ, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

/persons/resource/persons84063

Logothetis,  NK
Department Physiology of Cognitive Processes, Max Planck Institute for Biological Cybernetics, Max Planck Society;
Max Planck Institute for Biological Cybernetics, Max Planck Society;

Fulltext (restricted access)
There are currently no full texts shared for your IP range.
Fulltext (public)
There are no public fulltexts stored in PuRe
Supplementary Material (public)
There is no public supplementary material available
Citation

Shmuel, A., Yacoub, E., Chaimow, D., Logothetis, N., & Ugurbil, K. (2007). Spatio-temporal point-spread function of fMRI signal in human gray matter at 7 Tesla. NeuroImage, 35(2), 539-552. doi:10.1016/j.neuroimage.2006.12.030.


Cite as: https://hdl.handle.net/11858/00-001M-0000-0013-CE03-D
Abstract
This study investigated the spatio-temporal properties of blood-oxygenation level-dependent (BOLD) functional MRI (fMRI) signals in gray matter, excluding the confounding, inaccurate contributions of large blood vessels. We quantified the spatial specificity of the BOLD response, and we investigated whether this specificity varies as a function of time from stimulus onset. fMRI was performed at 7 Tesla (T), where mapping signals of parenchymal origin are easily detected. Two abutting visual stimuli were adjusted to elicit responses centered on a flat gray matter region in V1. fMRI signals were sampled at high-resolution orthogonal to the retinotopic boundary between the representations of the stimuli. Signals from macro-vessels were masked out. Principal component analysis revealed that the first component in space accounted for 96.2 ± 1.6% of the variance over time. The spatial profile of this time-invariant response was fitted with a model consisting of the convolution of a step function and a Gaussian point-spread-function (PSF). The mean full-width at half-maximal-height of the fitted PSF was 2.34 ± 0.20 mm. Based on simulations of confounding effects, we estimate that BOLD PSF in human gray matter is smaller than 2 mm. A time-point to time-point analysis revealed that the PSF obtained during the 3rd (1.52 mm) and 4th (1.99 mm) seconds of stimulation were narrower than the mean PSF obtained from the 5th second on (2.42 ± 0.15 mm). The position of the edge of the responding region was offset (1.72 ± 0.07 mm) from the boundary of the stimulated region, indicating a spatial non-linearity. Simulations showed that the effective contrast between active and non-active columns is reduced 25-fold when imaged using a PSF whose width is equal to the cycle of the imaged columnar organization.